"DCM-PB" and "DCM-OS" Control Board Sequence Flow Chart DCM-300BAH(-OS)

2.

 

 

 

 

 

 

 

 

 

 

 

 

 

4. 12-Hr. Drain Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DV opens for 20 min. every 12 hr.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See "12-Hr. Drain Cycle" below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FT Exceeded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cycle Steps

 

 

 

 

1. Fill Cycle

 

2. Ice Purge Cycle

3. Freeze Cycle

 

 

 

• FT exceeded: CB starts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shutdown sequence.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• FT 90 sec. starts when LF/S opens

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• WV energized continuously.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and terminated when UF/S closes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• When UF/S closes, 2. Ice

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refill

 

 

Purge Cycle starts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutdown Sequence

 

Startup begins here

 

 

 

 

 

 

 

 

 

 

60 sec.

 

 

 

 

 

 

 

Maximum 90 sec.

 

 

 

 

60 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.FT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exceeded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV continues until UF/S closes

Sequence Flow Chart

 

WV energized

 

LF/S closed

GM continues

UF/S open

LF/S closed

UF/S open

WV continues

 

UF/S open

UF/S closed

Comp energized

LF/S open

UF/S closed

GM continues

GM de-energizes

 

 

 

GM energized

FM energized

FT starts (90-sec.)

FT terminated

WV continues

 

 

 

 

 

 

 

 

WV de-energized

 

Comp continues

Comp continues

Comp de-energized

 

 

 

 

 

 

FM continues

FM continues

FM de-energized

 

11

 

 

 

 

GM continues

GM continues

 

 

 

 

 

 

WV energized

WV de-energized

 

 

 

 

 

 

 

 

 

Shutdown & Restart

 

 

 

1. Bin Full

 

 

 

2. Ice Purge Cycle

3. Icemaker Off

 

4. Icemaker

 

 

 

 

 

 

 

150-sec. Shutdown Sequence

 

 

 

Restart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 sec.

 

 

 

 

 

 

 

 

60 sec.

 

 

 

 

 

 

 

to "1. Fill Cycle" above

Legend:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BC-bin control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BC open

 

GM continues

 

GM de-energized BC closed

CB-control board

 

 

 

 

Comp-compressor

 

 

Comp continues Comp de-energized

 

 

 

 

 

 

 

 

DCT-drain cycle timer (12-hr. timer)

 

 

FM continues

 

FM de-energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DV-drain valve

 

 

GM continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DVT-drain valve timer (20-min. timer)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-Hr. Drain Cycle

 

 

 

 

1. Ice Purge Cycle

 

2. Drain

 

3. Icemaker

 

 

 

FM-fan motor

 

 

 

 

 

 

 

 

 

FT-fill timer (90-sec. low water safety timer)

 

 

 

 

 

 

Restart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GM-gear motor

 

 

 

 

 

 

 

60 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to "1. Fill Cycle" above

LF/S-lower float switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UF/S-upper float switch

DCT terminates

 

 

 

 

 

 

 

 

DVT terminates

 

 

 

DV energizes

 

 

 

WV-inlet water valve

DVT starts

GM de-energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GM continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Components Energized when the Control Switch is in the "DRAIN" Position

 

Comp de-energizes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The "DRAIN" position on the control switch is used when cleaning and sanitizing the icemaker. This allows

 

FM de-energizes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cleaner and sanitizer to drain from the reservoir and evaporator assembly. When switching to the "DRAIN"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position during the freeze cycle, the drain valve does not energize until the 150-sec. shutdown sequence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

terminates

(Shutdown & Restart).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: To bypass the 150-sec. shutdown sequence, move the power switch to the "OFF" position, place the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control switch in the "DRAIN" position, then move the power switch back to the "ON" position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 11
Image 11
Hoshizaki DCM 300BAH(-OS) service manual Sequence Flow Chart, Cycle Steps, Shutdown & Restart, 12-Hr. Drain Cycle

DCM 300BAH(-OS) specifications

The Hoshizaki DCM 300BAH(-OS) is a high-performance ice and water dispenser designed to meet the demands of various commercial environments. Known for its reliability and efficiency, this machine is widely used in restaurants, hotels, and catering services where a continuous supply of ice is essential.

One of the standout features of the DCM 300BAH(-OS) is its ability to produce crescent-shaped ice, which is favored in many settings for its hardness and slow-melting properties. This type of ice helps maintain the temperature of beverages longer without diluting them too quickly, making it ideal for mixed drinks and soft drinks alike.

Technology-wise, the Hoshizaki DCM 300BAH(-OS) integrates advanced refrigeration components that enhance energy efficiency. The machine is designed with a patented cooling system that reduces energy consumption while maintaining optimal ice production. Moreover, it is equipped with a highly efficient compressor that ensures quick recovery times even during peak usage.

One characteristic that sets this model apart is its space-saving design. With a footprint that allows for easy placement in tight quarters, it is particularly suited for establishments with limited counter space. The sleek and contemporary exterior also means it complements a variety of decor styles, making it a versatile addition to any commercial kitchen or bar.

The unit boasts a user-friendly interface, with easy-to-read indicators for ice and water levels, allowing staff to manage operations seamlessly. Additionally, the DCM 300BAH(-OS) features a self-cleaning cycle, which automates the sanitation process to ensure the utmost hygiene standards are maintained. This feature not only saves time but also enhances the longevity of the unit by reducing wear and tear.

Its durable construction is another strong point. Built from high-quality stainless steel, the DCM 300BAH(-OS) is resistant to corrosion and wear, ensuring it can withstand the rigors of daily use. Furthermore, Hoshizaki products are renowned for their reliability, and this model upholds that reputation, providing consistent performance with minimal downtime.

In summary, the Hoshizaki DCM 300BAH(-OS) stands out for its efficient ice production, innovative technology, space-saving design, user-friendly features, and robust durability, making it an ideal choice for any business that requires a reliable ice and water dispensing solution.