2. Control Switch
The control switch is a
a)ICE
When the control switch is in the "ICE" position, the control switch directs 5VDC from control board K4 connector pin #3 to control board K4 connector pin #4. When the control board receives 5VDC on K4 connector pin #4, the icemaking process starts.
b)DRAIN
When the control switch is in the "DRAIN" position, the control switch directs 24VAC power supply to the drain valve and breaks the 5VDC to the control board K4 connector pin #4.
CONTROL
ICE
OFF
DRAIN
3. Dispense Mode Switch
The dispense mode switch has 2 positions, "CONTINUOUS" and "PORTION."
a)CONTINUOUS
When the dispense mode switch is in the "CONTINUOUS" position, ice dispenses continuously for a maximum of 60 seconds per activation.
b)PORTION
When the dispense mode switch is in the "PORTION" position, ice dispenses for the amount of time determined by the ice dispense time setting.
DISPENSE MODE
PORTION
CONTINUOUS
The ice dispense time control is located on the control board. The dial indicates dispense time in seconds and is adjustable between 0.6 and 20 seconds. When shipped, the ice dispense time control is set to the minimum dispense time of 0.6 sec. (approximately 0.72 oz.).
Ice Dispense Time Control
16