Hoshizaki DCM 300BAH(-OS) service manual B. Important Notes for Component Replacement

Models: DCM 300BAH(-OS)

1 55
Download 55 pages 53.01 Kb
Page 40
Image 40
B.Important Notes for Component Replacement

4)Close the low-side valve and high-side valve on the gauge manifold.

5)Disconnect the gauge manifold hose from the vacuum pump and attach it to a refrigerant service cylinder. Remember to loosen the connection and purge the air from the hose. See the rating label inside the icemaker for the required refrigerant charge. Hoshizaki recommends only virgin refrigerant or reclaimed refrigerant which meets ARI Standard 700 (latest edition) be used.

6)A liquid charge is required for charging an R-404A system (to prevent fractionation). Place the service cylinder on the scales: if the service cylinder is not equipped with a dip tube, invert the service cylinder, then place it on the scales. Open the high-side valve on the gauge manifold.

7)Allow the system to charge with liquid until the proper charge weight is met.

8)If necessary, add any remaining charge to the system through the low-side.

NOTICE! To prevent compressor damage, use a throttling valve or liquid dispensing device to add the remaining liquid charge through the low-side access valve with the icemaker running.

9)Close the high and low-side gauge manifold valves, then disconnect the gauge manifold hoses.

10)Cap the access valves to prevent a possible leak.

B.Important Notes for Component Replacement

NOTICE

When replacing a component listed below, see the notes to help ensure proper operation.

Component

Notes

Compressor

Install a new drier, start capacitor, and start relay.

Expansion Valve

• Install a new drier.

 

• Attach the expansion valve bulb to the suction line in the same location as the previous

 

bulb.

 

• The bulb should be between the 10 and 2 o'clock positions on the tube.

 

• Secure the bulb with the clamp and holder, then insulate it.

 

 

Upper and

• Inspect the upper bearing for wear. See "V.B.1. Upper Bearing Wear Check." Replace if

Lower Bearings

necessary.

 

• When replacing the upper bearing it is advised to also change the lower bearing at the

 

same time.

 

 

Evaporator

• Install a new drier.

 

• Inspect the mechanical seal and O-ring prior to installing the new evaporator. If worn,

 

cracked, or scratched, the mechanical seal should also be replaced.

 

 

Gear Motor

Install a new gear motor capacitor.

 

 

40

Page 40
Image 40
Hoshizaki DCM 300BAH(-OS) service manual B. Important Notes for Component Replacement