3. Opti-Serve (OS) Sensors
Be sure to check all items in section "IV.F.2. Ice/Water Dispense" prior to using this chart. Use the following charts along with the wiring diagram to troubleshoot the OS sensors.
| Ice Sensor |
1. OS Sensor | a) Dirty. |
|
|
| b) Defective. See chart 3a and 3b. |
|
|
2. Control Board | a) No power to infrared sensor. |
|
|
| b) Not reading infrared sensor signal. |
| Water Sensor |
|
|
1. OS Sensor | a) Dirty. |
|
|
| b) Defective. See chart 3c. |
|
|
2. Control Board | a) No power to infrared sensor. |
| b) Not reading infrared sensor signal. |
|
|
3a. Ice Dispense "Continuous"
Component | Control Board | Sensor | To | Control Board /Other | Sensor | Engaged | Disengaged | |
Solenoid | K2 Pin 6 (LBU wire) | - | To | Neutral/GND | - | 120VAC | 0VAC | |
Sensor | K5 Pin 4 (W/0 wire) | (R wire) | To | K5 Pin 5 (Y wire) | (W wire) | 5VDC | 0VDC | |
K5 Pin 6 (W/BR wire) | (BK wire) | 5VDC | 5VDC | |||||
|
|
|
|
3b. Ice Dispense "Portion"
Component | Control Board | Sensor | To | Control Board /Other | Sensor | Engaged | Disengaged | |||
|
|
|
|
|
|
|
|
|
| |
Solenoid | K2 | Pin 6 | (LBU wire) | - | To | Neutral/GND | - | 120VAC | 0VAC | |
Sensor | K5 | Pin 1 | (W/R wire) | (R wire) | To | K5 Pin 2 (W/BU wire) | (W wire) | 5VDC | 0VDC | |
K5 Pin 3 (W/BK wire) | (BK wire) | 5VDC | 5VDC | |||||||
|
|
|
|
|
|
3c. Water Dispense
Component | Control Board | To | Control Board /Other | Engaged | Disengaged | |
Solenoid | K2 Pin 8 (DBU wire) | To | K4 Pin 2 (LBU wire) | 24VAC | 0VAC | |
Sensor | K5 Pin 7 (R wire) | To | K5 Pin 8 (W wire) | 5VDC | 0VDC | |
K5 Pin 9 (BK wire) | 5VDC | 5VDC | ||||
|
|
|
37