Problem

Possible Cause

 

Remedy

 

 

 

 

 

j) Water Control Relay

1. Bad contacts.

1. Replace.

 

 

 

 

 

 

2. Open coil.

2. Replace.

 

 

 

 

 

k) Water Valve

1. Coil winding opened.

1. Replace.

 

 

 

 

 

l) Shut-off Valve

1. Closed.

1. Open.

 

 

 

 

 

 

2. Water failure.

2. Wait until water is

 

 

 

supplied.

 

 

 

 

 

m)Plug and Receptacle

1. Disconnected.

1. Connect.

 

(Control Box)

 

 

 

2. Loose terminal.

2. Repair terminal

 

 

 

 

 

connection.

 

 

 

 

[2] Water does not stop,

a) Float Switch

1. Bad contacts.

1. Check for continuity and

and the gear motor

 

 

replace.

will not start.

 

 

 

 

2. Float does not move

2. Clean or replace.

 

 

 

 

freely.

 

 

 

 

 

 

b) Water Control Relay

1. Contact fused.

1. Replace.

 

 

 

 

 

 

2. Coil winding opened.

2. Replace.

 

 

 

 

 

c) Flush Water Valve

1. Valve seat clogged

1. Clean or replace.

 

 

and water leaking.

 

 

 

 

 

 

d) Hoses

1. Disconnected.

1. Connect.

 

 

 

 

[3] Water has been

a) Bin Control

1. Open

1. Bin full, check for

supplied, but the gear

 

 

continuity on proximity

motor will not start.

 

 

switch.

 

 

 

 

 

b) Water Control Relay

1. Low water safety

1. Replace relay.

 

 

circuit open

 

 

 

(bad conacts ).

 

 

 

 

 

 

c) Control Timer

1. Fails to operate gear

1. Check water control relay

 

(Printed Circuit Board)

motor relay.

circuit.

 

 

 

 

 

d) Gear Motor Fuse

1. Blown.

1. Check gear motor

 

 

 

amperage, bearing

 

 

 

wear (see "V. F. 1. Upper

 

 

 

Bearing Wear Check"),

 

 

 

supply voltage.

 

 

 

 

 

e) Gear Motor Thermal

1. Open.

1. Check gear motor

 

Protector

 

bearings, voltage supply.

 

 

 

 

 

f) Gear Motor

1. Open windings.

1. Replace gear motor.

 

 

 

 

 

 

2. Locked bearings

1. Replace gear motor.

 

 

 

 

[4] Gear motor starts,

a) Gear Motor Protect

1. Open coil.

1. Replace.

but compressor will

Relay

 

 

2. Open contacts.

2. Replace.

not start or operates

 

 

 

 

b) Timer Board Relay

1. Bad contacts.

1. Check for continuity and

intermittently.

 

 

replace.

 

 

 

 

 

 

 

 

 

2. Coil winding opened.

2. Replace timer.

 

 

 

 

 

c) Starter

1. Bad contacts.

1. Check for continuity and

 

 

 

replace.

 

 

 

 

 

 

2. Coil winding opened.

2. Replace.

 

 

 

 

 

 

3. Loose connections.

3. Tighten.

 

 

 

 

 

d) Start Capacitor or Run

1. Defective.

1. Replace.

 

Capacitor

 

 

 

 

 

 

30

Page 30
Image 30
Hoshizaki F-300BAF service manual Problem Possible Cause Remedy