Problem | Possible Cause |
| Remedy | |
|
|
|
| |
| j) Water Control Relay | 1. Bad contacts. | 1. Replace. | |
|
|
|
| |
|
| 2. Open coil. | 2. Replace. | |
|
|
|
| |
| k) Water Valve | 1. Coil winding opened. | 1. Replace. | |
|
|
|
| |
| l) | 1. Closed. | 1. Open. | |
|
|
|
| |
|
| 2. Water failure. | 2. Wait until water is | |
|
|
| supplied. | |
|
|
|
| |
| m)Plug and Receptacle | 1. Disconnected. | 1. Connect. | |
| (Control Box) |
|
| |
| 2. Loose terminal. | 2. Repair terminal | ||
|
| |||
|
|
| connection. | |
|
|
|
| |
[2] Water does not stop, | a) Float Switch | 1. Bad contacts. | 1. Check for continuity and | |
and the gear motor |
|
| replace. | |
will not start. |
|
|
| |
| 2. Float does not move | 2. Clean or replace. | ||
|
| |||
|
| freely. |
| |
|
|
|
| |
| b) Water Control Relay | 1. Contact fused. | 1. Replace. | |
|
|
|
| |
|
| 2. Coil winding opened. | 2. Replace. | |
|
|
|
| |
| c) Flush Water Valve | 1. Valve seat clogged | 1. Clean or replace. | |
|
| and water leaking. |
| |
|
|
|
| |
| d) Hoses | 1. Disconnected. | 1. Connect. | |
|
|
|
| |
[3] Water has been | a) Bin Control | 1. Open | 1. Bin full, check for | |
supplied, but the gear |
|
| continuity on proximity | |
motor will not start. |
|
| switch. | |
|
|
|
| |
| b) Water Control Relay | 1. Low water safety | 1. Replace relay. | |
|
| circuit open |
| |
|
| (bad conacts ). |
| |
|
|
|
| |
| c) Control Timer | 1. Fails to operate gear | 1. Check water control relay | |
| (Printed Circuit Board) | motor relay. | circuit. | |
|
|
|
| |
| d) Gear Motor Fuse | 1. Blown. | 1. Check gear motor | |
|
|
| amperage, bearing | |
|
|
| wear (see "V. F. 1. Upper | |
|
|
| Bearing Wear Check"), | |
|
|
| supply voltage. | |
|
|
|
| |
| e) Gear Motor Thermal | 1. Open. | 1. Check gear motor | |
| Protector |
| bearings, voltage supply. | |
|
|
|
| |
| f) Gear Motor | 1. Open windings. | 1. Replace gear motor. | |
|
|
|
| |
|
| 2. Locked bearings | 1. Replace gear motor. | |
|
|
|
| |
[4] Gear motor starts, | a) Gear Motor Protect | 1. Open coil. | 1. Replace. | |
but compressor will | Relay |
|
| |
2. Open contacts. | 2. Replace. | |||
not start or operates |
| |||
|
|
| ||
b) Timer Board Relay | 1. Bad contacts. | 1. Check for continuity and | ||
intermittently. | ||||
|
| replace. | ||
|
|
| ||
|
|
|
| |
|
| 2. Coil winding opened. | 2. Replace timer. | |
|
|
|
| |
| c) Starter | 1. Bad contacts. | 1. Check for continuity and | |
|
|
| replace. | |
|
|
|
| |
|
| 2. Coil winding opened. | 2. Replace. | |
|
|
|
| |
|
| 3. Loose connections. | 3. Tighten. | |
|
|
|
| |
| d) Start Capacitor or Run | 1. Defective. | 1. Replace. | |
| Capacitor |
|
| |
|
|
|
|
30