Hoshizaki F-300BAF B. Diagnostic Charts, No Ice Production, Problem, Possible Cause, Remedy

Models: F-300BAF

1 50
Download 50 pages 52.19 Kb
Page 29
Image 29

B. Diagnostic Charts

1. No Ice Production

Problem

Possible Cause

 

Remedy

 

 

 

 

[1] The icemaker will not

a) Power Supply

1. Off.

1. Turn on.

start. (fill cycle, water

 

 

 

 

2. Power cord

2. Plug into receptacle.

valve)

 

unplugged.

 

 

 

 

 

 

 

 

 

 

3. Loose connection.

3. Tighten.

 

 

 

 

 

 

4. Bad contacts.

4. Check for contintinuity and

 

 

 

replace.

 

 

 

 

 

 

5. Blown fuse.

5. Replace.

 

 

 

 

 

b) Power Switch

1. OFF position.

1. Move to ON position.

 

(Control Box)

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

 

 

replace.

 

 

 

 

 

c) High Pressure Switch

1. Dirty air filter or

1. Clean.

 

 

condenser.

 

 

 

 

 

 

 

2. Ambient or condenser

2. Reduce temperature.

 

 

water temperature too

 

 

 

warm.

 

 

 

 

 

 

 

3. Condenser water

3. Check and get

 

 

pressure too low or off.

recommended pressure.

 

 

(water-cooled model

 

 

 

only)

 

 

 

 

 

 

 

4. Water regulating valve

4. Adjust it lower.

 

 

set too high. (water-

 

 

 

cooled model only)

 

 

 

 

 

 

 

5. Fan not rotating.

5. See "3. [1] a) Fan Motor.”

 

 

 

 

 

 

6. Refrigerant

6. Recharge.

 

 

overcharged.

 

 

 

 

 

 

 

7. Refrigerant line or

7. Clean and replace drier.

 

 

components plugged.

 

 

 

 

 

 

 

8. Bad contacts.

8. Check for continuity and

 

 

 

replace.

 

 

 

 

 

 

9. Loose connections.

9. Tighten.

 

 

 

 

 

d) Transformer

1. Coil winding opened.

1. Replace.

 

 

 

 

 

e) Spout Safety Switch

1. Bin control not

1. Check bin control actuator

 

and Relay

activating.

and proximity switch.

 

 

 

 

 

f) Fuse (Control Box)

1. Blown.

1. Check for short circuit and

 

 

 

replace.

 

 

 

 

 

g) Bin Control

1. Actuator sticking.

1. Adjust or replace.

 

 

 

 

 

 

2. Proximity switch open.

2. Replace.

 

 

 

 

 

h) Flush Switch

1. FLUSH position.

1. Move to ICE position.

 

 

 

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

replace.

 

 

 

 

 

i) Flush Switch Relay

1. Coil open.

1. Replace.

 

 

 

 

29

Page 29
Image 29
Hoshizaki F-300BAF service manual B. Diagnostic Charts, No Ice Production, Problem, Possible Cause, Remedy