D. Performance Data

1. F-300BAF

APPROXIMATE

Ambient

 

 

Water Temp. (°F)

 

ICE PRODUCTION

Temp. (°F)

 

50

 

70

 

 

90

PER 24 HR.

70

*303

*(137)

290

(131)

 

278

(126)

 

80

267

(121)

256

(116)

 

246

(112)

 

90

236

(107)

*232

*(105)

 

218

(99)

lbs./day (kg/day)

100

209

(95)

201

(91)

 

*188

*(85)

APPROXIMATE ELECTRIC

70

*667

--

668

--

 

669

--

CONSUMPTION

80

670

--

671

--

 

672

--

 

90

673

--

*674

--

 

681

--

watts

100

688

--

695

--

 

*702

--

APPROXIMATE WATER

70

*36

*(137)

35

(131)

 

33

(126)

CONSUMPTION PER 24 HR.

80

32

(121)

31

(116)

 

30

(112)

gal./day (l/day)

90

28

(107)

*28

*(105)

 

26

(99)

100

25

(95)

24

(91)

 

*23

*(85)

EVAPORATOR OUTLET TEMP.

70

*19

*(-7)

19

(-7)

 

19

(-7)

 

80

19

(-7)

22

(-6)

 

22

(-6)

 

90

22

(-6)

*22

*(-6)

 

26

(-4)

°F (°C)

100

26

(-4)

26

(-4)

 

*26

*(-4)

HEAD PRESSURE

70

*250

*(17.5)

250

(17.5)

 

250

(17.5)

 

80

280

(19.7)

280

(19.7)

 

280

(19.7)

PSIG (kg/cm²G)

90

311

(21.9)

*311

*(21.9)

 

311

(21.9)

100

351

(24.7)

351

(24.7)

 

*351

*(24.7)

SUCTION PRESSURE

70

*35

*(2.5)

35

(2.5)

 

35

(2.5)

 

80

37

(2.6)

37

(2.6)

 

37

(2.6)

PSIG ( kg/cm²G )

90

39

(2.7)

*39

*(2.7)

 

39

(2.7)

100

43

(3.0)

43

(3.0)

 

*43

*(3.0)

TOTAL HEAT OF REJECTION

 

3178 BTU/h (AT 90°F /WT 70°F)

 

 

Note: The data without *marks should be used for reference.

We reserve the right to make changes to specifications and design without prior notice.

26

Page 26
Image 26
Hoshizaki F-300BAF service manual Performance Data, ICE Production