Problem | Possible Cause |
| Remedy | |
|
|
|
|
|
| e) Compressor | 1. Loose connections. | 1. | Tighten. |
|
|
|
|
|
|
| 2. Motor winding opened | 2. | Replace. |
|
| or grounded. |
|
|
|
|
|
|
|
|
| 3. Compressor locked | 3. | Replace compressor. |
|
| and motor protector |
|
|
|
| tripped. |
|
|
|
|
|
|
|
| f) Power Supply | 1. Circuit ampacity too | 1. | Install a |
|
| low. |
| circuit. |
|
|
|
|
|
[5] Gear motor and | a) Refrigerant Line | 1. Gas leaks. | 1. | Check for leaks with a |
compressor start, but |
|
|
| leak detector. Replace |
no ice is produced. |
|
|
| drier and charge with |
|
|
|
| refrigerant. Refrigerant |
|
|
|
| charge is marked on |
|
|
|
| nameplate or rating label. |
|
|
|
|
|
|
| 2. Refrigerant line | 2. | Replace the clogged |
|
| clogged. |
| component. |
|
|
|
|
|
2. Low Ice Production
Problem | Possible Cause |
| Remedy |
|
|
|
|
[1] Low ice production. | a)Refrigerant Line | 1. Gas leaks. | 1. See "2. [5] a) Refrigerant |
|
|
| Line." |
|
|
|
|
|
| 2. Refrigerant line | 2. Replace the clogged |
|
| clogged. | component. |
|
|
|
|
|
| 3. Overcharged. | 3. Recharge. |
|
|
|
|
| 1. Dirty air filter or | 1. Clean. | |
| High | condenser. |
|
|
|
|
|
|
| 2. Ambient or condenser | 2. Reduce temperature. |
|
| water temperature too |
|
|
| warm. |
|
|
|
|
|
|
| 3. Condenser water | 3. Check and get recom- |
|
| pressure too low or off. | mended pressure. |
|
|
| |
|
| only] |
|
|
|
|
|
|
| 4. Fan, slow rpm. | 4. See "3. [1] a) Fan Motor". |
|
|
|
|
|
| 5. Water regulating valve | 5. Clean. |
|
| clogged. |
|
|
| model only] |
|
|
|
|
|
| c) Expansion Valve (not | 1. | 1. Replace. |
| adjustable) | low. |
|
|
|
|
|
|
| 2. | 2. See if expansion valve |
|
| high. | bulb is mounted properly, |
|
|
| and replace the valve if |
|
|
| necessary. |
|
|
|
|
31