Hoshizaki F-300BAF Sanitizing Solution, Evaporator Assembly, Spout A Spout A Packing

Models: F-300BAF

1 50
Download 50 pages 52.19 Kb
Page 46
Image 46
Evaporator Assembly

8) Remove the thumbscrews attaching spout

Thumbscrews

 

(A) to the evaporator assembly and lift off

 

spout (A) and spout packing (A). See Fig 4.

 

9) Pour the cleaning solution over the

Evaporator Assembly

extruding head until the evaporator

 

assembly and the reservoir are filled and

 

the solution starts to overflow into the drain

 

pan.

 

 Spout (A) Spout (A)

Spout (A) Packing

Fig. 4

Note: If there is excess scale on the extruding head, fill the evaporator assembly and reservoir as described above, then use a clamp on the reservoir hose between the reservoir and evaporator assembly to block flow. Pour additional cleaning fluid over the extruding head until the evaporator assembly is completely full.

10)Using the thumbscrews, replace spouts (A) and (B) and spout packings (A) and (B) in their correct positions.

11)Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on the reservoir hose in step 9, remove it before operation.

12)Move the flush switch to the "ICE" position, then turn on the power supply. Replace the top panel and the front panel in their correct positions. Make ice using the solution until the icemaker stops making ice.

13)Remove the front panel.

14)Move the flush switch to the "FLUSH" position to drain the remainder of the solution.

15)After the solution is drained, move the flush switch to the "ICE" position.

16)Replace the front panel in its correct position.

17)Open the water supply line shut-off valve, and supply water to the reservoir.

18)When the gear motor starts, remove the top panel and front panel. Turn off the power supply.

19)Drain out all water from the water line. See 4) through 6).

3. Sanitizing Solution

Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 5 gallons (19 l) of warm water.

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after dilution.

46

Page 46
Image 46
Hoshizaki F-300BAF service manual Sanitizing Solution, Evaporator Assembly, Spout A Spout A Packing