[d] KM-1300SAH3
APPROXIMATE ICE | AMBIENT TEMP. |
|
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
|
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 |
| 1320 | 599 |
| 1265 | 574 |
| 1153 | 523 |
|
|
|
| 80/27 |
| 1278 | 580 |
| 1192 | 541 |
| 1060 | 481 |
lbs./day |
| kg./day | 90/32 |
| 1265 | 574 |
| 1132 | 513 |
| 1006 | 456 | |
| 100/38 |
| 1230 | 558 |
| 1102 | 500 |
| 890 | 404 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 70/21 |
|
| 2150 |
|
| 2197 |
|
| 2239 |
|
|
|
| 80/27 |
|
| 2186 |
|
| 2259 |
|
| 2289 |
|
|
|
| 90/32 |
|
| 2197 |
|
| 2311 |
|
| 2347 |
watts |
|
|
| 100/38 |
|
| 2198 |
|
| 2320 |
|
| 2380 |
APPROXIMATE WATER | 70/21 |
| 632 | 2.39 |
| 525 | 1.99 |
| 476 | 1.80 | |||
CONSUMPTION PER 24 HR. | 80/27 |
| 551 | 2.08 |
| 385 | 1.46 |
| 389 | 1.47 | |||
|
|
|
| 90/32 |
| 525 | 1.99 |
| 267 | 1.01 |
| 248 | 0.94 |
gal./day |
| m3/day | 100/38 |
| 406 | 1.54 |
| 263 | 0.99 |
| 231 | 0.87 | |
FREEZING CYCLE TIME | 70/21 |
|
| 30 |
|
| 32 |
|
| 36 | |||
|
|
|
| 80/27 |
|
| 32 |
|
| 35 |
|
| 39 |
|
|
|
| 90/32 |
|
| 32 |
|
| 37 |
|
| 41 |
min. |
|
|
| 100/38 |
|
| 33 |
|
| 38 |
|
| 45 |
HARVEST CYCLE TIME | 70/21 |
|
| 4.0 |
|
| 3.4 |
|
| 3.2 | |||
|
|
|
| 80/27 |
|
| 3.6 |
|
| 2.7 |
|
| 2.8 |
|
|
|
| 90/32 |
|
| 3.4 |
|
| 2.1 |
|
| 2.0 |
min. |
|
|
| 100/38 |
|
| 2.8 |
|
| 2.1 |
|
| 2.0 |
HEAD PRESSURE | 70/21 |
| 255 | 17.9 |
| 274 | 19.3 |
| 296 | 20.8 | |||
|
|
|
| 80/27 |
| 270 | 18.9 |
| 299 | 21.0 |
| 318 | 22.4 |
|
|
|
| 90/32 |
| 274 | 19.3 |
| 320 | 22.5 |
| 341 | 24.0 |
PSIG | kg/cm2G | 100/38 |
| 277 | 19.5 |
| 325 | 22.8 |
| 360 | 25.3 | ||
SUCTION PRESSURE | 70/21 |
| 47 | 3.3 |
| 48 | 3.4 |
| 50 | 3.5 | |||
|
|
|
| 80/27 |
| 48 | 3.4 |
| 50 | 3.5 |
| 52 | 3.6 |
|
|
|
| 90/32 |
| 48 | 3.4 |
| 52 | 3.7 |
| 54 | 3.8 |
PSIG | kg/cm2G | 100/38 |
| 49 | 3.4 |
| 52 | 3.7 |
| 55 | 3.9 | ||
TOTAL HEAT OF REJECTION FROM CONDENSER |
| 18,130 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in bold should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
40