[e] KM-1300SWH3
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 | 1254 | 569 |
| 1264 | 573 |
| 1191 | 540 |
|
|
|
| 80/27 | 1261 | 572 |
| 1276 | 579 |
| 1157 | 525 |
|
|
|
| 90/32 | 1264 | 573 |
| 1287 | 584 |
| 1186 | 538 |
lbs./day |
| kg./day |
| 100/38 | 1220 | 554 |
| 1263 | 573 |
| 1093 | 496 |
|
|
|
|
|
|
|
|
|
| |||
APPROXIMATE ELECTRIC | 70/21 |
| 2090 |
|
| 2090 |
|
| 2092 | |||
CONSUMPTION | 80/27 |
| 2090 |
|
| 2091 |
|
| 2093 | |||
|
|
|
| 90/32 |
| 2090 |
|
| 2091 |
|
| 2093 |
watts |
|
|
| 100/38 |
| 2091 |
|
| 2092 |
|
| 2095 |
APPROXIMATE WATER | 70/21 | 1215 | 4.60 |
| 1216 | 4.60 |
| 1581 | 5.99 | |||
CONSUMPTION PER 24 HR. | 80/27 | 1216 | 4.60 |
| 1218 | 4.61 |
| 1785 | 6.76 | |||
|
|
|
| 90/32 | 1216 | 4.60 |
| 1219 | 4.61 |
| 1708 | 6.47 |
gal./day |
| m3/day | 100/38 | 1750 | 6.62 |
| 1333 | 5.05 |
| 2158 | 8.17 | |
FREEZING CYCLE TIME | 70/21 |
| 30 |
|
| 31 |
|
| 33 | |||
|
|
|
| 80/27 |
| 31 |
|
| 32 |
|
| 34 |
|
|
|
| 90/32 |
| 31 |
|
| 33 |
|
| 35 |
min. |
|
|
| 100/38 |
| 32 |
|
| 33 |
|
| 37 |
|
|
|
|
|
|
|
|
|
| |||
HARVEST CYCLE TIME | 70/21 |
| 4.2 |
|
| 3.6 |
|
| 3.3 | |||
|
|
|
| 80/27 |
| 3.8 |
|
| 2.8 |
|
| 2.9 |
|
|
|
| 90/32 |
| 3.6 |
|
| 2.2 |
|
| 2.1 |
min. |
|
|
| 100/38 |
| 3.0 |
|
| 2.2 |
|
| 2.0 |
HEAD PRESSURE | 70/21 | 270 | 19.0 |
| 274 | 19.3 |
| 284 | 19.9 | |||
|
|
|
| 80/27 | 273 | 19.2 |
| 280 | 19.7 |
| 291 | 20.5 |
|
|
|
| 90/32 | 274 | 19.3 |
| 285 | 20.0 |
| 295 | 20.8 |
PSIG | kg/cm2G | 100/38 | 277 | 19.5 |
| 287 | 20.2 |
| 305 | 21.4 | ||
SUCTION PRESSURE | 70/21 | 48 | 3.4 |
| 49 | 3.4 |
| 50 | 3.5 | |||
|
|
|
| 80/27 | 49 | 3.4 |
| 50 | 3.5 |
| 51 | 3.6 |
|
|
|
| 90/32 | 49 | 3.4 |
| 51 | 3.6 |
| 52 | 3.7 |
PSIG | kg/cm2G | 100/38 | 49 | 3.4 |
| 51 | 3.6 |
| 53 | 3.7 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 15,450 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 2560 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
WATER FLOW FOR CONDENSER | 88 gal. / h (AT 100ºF (38ºC) / WT 90ºF (32ºC)) |
PRESSURE DROP OF COOLING WATER LINE | less than 10 PSIG |
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in bold should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
41