[b] KM-1300SWH
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 | 1284 | 582 |
| 1282 | 582 |
| 1208 | 548 |
|
|
|
| 80/27 | 1283 | 582 |
| 1280 | 581 |
| 1166 | 529 |
|
|
|
| 90/32 | 1282 | 582 |
| 1278 | 580 |
| 1180 | 535 |
lbs./day |
| kg./day |
| 100/38 | 1243 | 564 |
| 1255 | 569 |
| 1089 | 494 |
|
|
|
|
|
|
|
|
|
| |||
APPROXIMATE ELECTRIC | 70/21 |
| 2033 |
|
| 2061 |
|
| 2108 | |||
CONSUMPTION | 80/27 |
| 2055 |
|
| 2099 |
|
| 2149 | |||
|
|
|
| 90/32 |
| 2061 |
|
| 2130 |
|
| 2180 |
watts |
|
|
| 100/38 |
| 2073 |
|
| 2142 |
|
| 2225 |
APPROXIMATE WATER | 70/21 | 1587 | 6.01 |
| 1474 | 5.58 |
| 1889 | 7.15 | |||
CONSUMPTION PER 24 HR. | 80/27 | 1501 | 5.68 |
| 1326 | 5.02 |
| 2057 | 7.79 | |||
|
|
|
| 90/32 | 1474 | 5.58 |
| 1203 | 4.55 |
| 1808 | 6.85 |
gal./day |
| m3/day | 100/38 | 1750 | 6.62 |
| 1345 | 5.09 |
| 2365 | 8.95 | |
FREEZING CYCLE TIME | 70/21 |
| 32 |
|
| 33 |
|
| 35 | |||
|
|
|
| 80/27 |
| 32 |
|
| 33 |
|
| 36 |
|
|
|
| 90/32 |
| 33 |
|
| 34 |
|
| 37 |
min. |
|
|
| 100/38 |
| 33 |
|
| 35 |
|
| 39 |
|
|
|
|
|
|
|
|
|
| |||
HARVEST CYCLE TIME | 70/21 |
| 4.3 |
|
| 3.7 |
|
| 3.4 | |||
|
|
|
| 80/27 |
| 3.9 |
|
| 2.9 |
|
| 2.9 |
|
|
|
| 90/32 |
| 3.7 |
|
| 2.3 |
|
| 2.1 |
min. |
|
|
| 100/38 |
| 3.8 |
|
| 2.3 |
|
| 2.0 |
HEAD PRESSURE | 70/21 | 275 | 19.3 |
| 278 | 19.5 |
| 288 | 20.2 | |||
|
|
|
| 80/27 | 277 | 19.5 |
| 282 | 19.8 |
| 295 | 20.7 |
|
|
|
| 90/32 | 278 | 19.5 |
| 285 | 20.0 |
| 297 | 20.9 |
PSIG | kg/cm2G | 100/38 | 282 | 19.8 |
| 288 | 20.2 |
| 308 | 21.7 | ||
SUCTION PRESSURE | 70/21 | 47 | 3.3 |
| 48 | 3.3 |
| 49 | 3.4 | |||
|
|
|
| 80/27 | 47 | 3.3 |
| 48 | 3.4 |
| 49 | 3.5 |
|
|
|
| 90/32 | 48 | 3.3 |
| 49 | 3.4 |
| 50 | 3.5 |
PSIG | kg/cm2G | 100/38 | 48 | 3.4 |
| 49 | 3.5 |
| 51 | 3.6 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 15,560 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 2650 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
WATER FLOW FOR CONDENSER | 88 gal. / h (AT 100ºF (38ºC) / WT 90ºF (32ºC)) |
PRESSURE DROP OF COOLING WATER LINE | less than 10 PSIG |
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in bold should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
38