4.Performance Data
[a]KM-1300SAH
APPROXIMATE ICE | AMBIENT TEMP. |
|
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
|
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 |
| 1283 | 582 |
| 1242 | 563 |
| 1135 | 515 |
|
|
|
| 80/27 |
| 1252 | 568 |
| 1188 | 539 |
| 1053 | 478 |
lbs./day |
| kg./day |
| 90/32 |
| 1242 | 563 |
| 1143 | 518 |
| 1017 | 461 |
| 100/38 |
| 1203 | 546 |
| 1114 | 505 |
| 902 | 409 | |||
|
|
|
|
|
|
|
|
|
|
| |||
APPROXIMATE ELECTRIC | 70/21 |
|
| 2180 |
|
| 2225 |
|
| 2295 | |||
CONSUMPTION | 80/27 |
|
| 2214 |
|
| 2284 |
|
| 2358 | |||
|
|
|
| 90/32 |
|
| 2225 |
|
| 2334 |
|
| 2407 |
watts |
|
|
| 100/38 |
|
| 2242 |
|
| 2351 |
|
| 2475 |
APPROXIMATE WATER | 70/21 |
| 697 | 2.64 |
| 588 | 2.23 |
| 514 | 1.94 | |||
CONSUMPTION PER 24 HR. | 80/27 |
| 614 | 2.32 |
| 446 | 1.69 |
| 412 | 1.56 | |||
|
|
|
| 90/32 |
| 588 | 2.23 |
| 327 | 1.24 |
| 274 | 1.04 |
gal./day |
| m3/day | 100/38 |
| 456 | 1.73 |
| 315 | 1.19 |
| 226 | 0.85 | |
FREEZING CYCLE TIME | 70/21 |
|
| 30 |
|
| 32 |
|
| 36 | |||
|
|
|
| 80/27 |
|
| 32 |
|
| 35 |
|
| 39 |
|
|
|
| 90/32 |
|
| 32 |
|
| 37 |
|
| 41 |
min. |
|
|
| 100/38 |
|
| 33 |
|
| 38 |
|
| 44 |
HARVEST CYCLE TIME | 70/21 |
|
| 4.5 |
|
| 3.8 |
|
| 3.5 | |||
|
|
|
| 80/27 |
|
| 4.0 |
|
| 2.9 |
|
| 3.0 |
|
|
|
| 90/32 |
|
| 3.8 |
|
| 2.2 |
|
| 2.1 |
min. |
|
|
| 100/38 |
|
| 3.1 |
|
| 2.2 |
|
| 2.0 |
HEAD PRESSURE | 70/21 |
| 255 | 17.9 |
| 273 | 19.2 |
| 296 | 20.8 | |||
|
|
|
| 80/27 |
| 268 | 18.9 |
| 296 | 20.8 |
| 318 | 22.4 |
|
|
|
| 90/32 |
| 273 | 19.2 |
| 315 | 22.1 |
| 338 | 23.8 |
PSIG | kg/cm2G | 100/38 |
| 277 | 19.5 |
| 320 | 22.5 |
| 360 | 25.3 | ||
SUCTION PRESSURE | 70/21 |
| 45 | 3.2 |
| 47 | 3.3 |
| 49 | 3.4 | |||
|
|
|
| 80/27 |
| 46 | 3.3 |
| 49 | 3.5 |
| 51 | 3.6 |
|
|
|
| 90/32 |
| 47 | 3.3 |
| 51 | 3.6 |
| 53 | 3.7 |
PSIG | kg/cm2G | 100/38 |
| 47 | 3.3 |
| 51 | 3.6 |
| 55 | 3.9 | ||
TOTAL HEAT OF REJECTION FROM CONDENSER |
| 19,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in bold should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
37