[f] KM-1300SRH3
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 | 1308 | 593 |
| 1296 | 588 |
| 1203 | 546 |
|
|
|
| 80/27 | 1299 | 589 |
| 1279 | 580 |
| 1145 | 520 |
lbs./day |
| kg./day |
| 90/32 | 1296 | 588 |
| 1266 | 574 |
| 1148 | 521 |
| 100/38 | 1252 | 568 |
| 1238 | 562 |
| 1039 | 471 | |||
|
|
|
|
|
|
|
|
|
| |||
APPROXIMATE ELECTRIC | 70/21 |
| 2270 |
|
| 2285 |
|
| 2332 | |||
CONSUMPTION | 80/27 |
| 2281 |
|
| 2305 |
|
| 2367 | |||
|
|
|
| 90/32 |
| 2285 |
|
| 2321 |
|
| 2378 |
watts |
|
|
| 100/38 |
| 2303 |
|
| 2334 |
|
| 2430 |
APPROXIMATE WATER | 70/21 | 706 | 2.67 |
| 573 | 2.17 |
| 531 | 2.01 | |||
CONSUMPTION PER 24 HR. | 80/27 | 605 | 2.29 |
| 397 | 1.50 |
| 434 | 1.64 | |||
|
|
|
| 90/32 | 573 | 2.17 |
| 251 | 0.95 |
| 253 | 0.96 |
gal./day |
| m3/day | 100/38 | 432 | 1.63 |
| 251 | 0.95 |
| 256 | 0.97 | |
FREEZING CYCLE TIME | 70/21 |
| 30 |
|
| 31 |
|
| 33 | |||
|
|
|
| 80/27 |
| 31 |
|
| 32 |
|
| 35 |
|
|
|
| 90/32 |
| 31 |
|
| 33 |
|
| 36 |
min. |
|
|
| 100/38 |
| 32 |
|
| 34 |
|
| 39 |
HARVEST CYCLE TIME | 70/21 |
| 4.8 |
|
| 4.0 |
|
| 3.7 | |||
|
|
|
| 80/27 |
| 4.2 |
|
| 3.0 |
|
| 3.1 |
|
|
|
| 90/32 |
| 4.0 |
|
| 2.2 |
|
| 2.1 |
min. |
|
|
| 100/38 |
| 3.2 |
|
| 2.2 |
|
| 2.0 |
HEAD PRESSURE | 70/21 | 230 | 16.2 |
| 242 | 17.0 |
| 259 | 18.2 | |||
|
|
|
| 80/27 | 239 | 16.8 |
| 257 | 18.1 |
| 275 | 19.4 |
|
|
|
| 90/32 | 242 | 17.0 |
| 270 | 19.0 |
| 288 | 20.3 |
PSIG | kg/cm2G | 100/38 | 246 | 17.3 |
| 274 | 19.3 |
| 305 | 21.4 | ||
SUCTION PRESSURE | 70/21 | 50 | 3.5 |
| 51 | 3.6 |
| 53 | 3.7 | |||
|
|
|
| 80/27 | 51 | 3.6 |
| 52 | 3.7 |
| 55 | 3.9 |
|
|
|
| 90/32 | 51 | 3.6 |
| 53 | 3.7 |
| 56 | 3.9 |
PSIG | kg/cm2G | 100/38 | 52 | 3.6 |
| 54 | 3.8 |
| 58 | 4.1 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 16600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 2500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
CONDENSER VOLUME | 132 CU. IN |
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in bold should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
42