Set clock options

Stratum 3 clock wiring installation procedure

1.Connect the B25A cables from the TN780 connector panel slot on the system cabinet and the Stratum 3 Clock to the cross-connect module in the yellow field.

2.Connect the CSU plug end of the H-600-274 Y-cable to the primary CSU. Route an H600-307 cable from the DS1 connector panel slot on the system cabinet to the connector on the “SYSTEM” end of the Y-cable.

3.Route a B25A cable from the “CLOCK” end of the Y-cable to the cross- connect module in the yellow field.

4.Repeat steps 2 and 3 for the secondary CSU. The maximum allowable cabling distance between the Stratum 3 clock and the CSU is shown in the table below.

Table 19. Maximum cabling distance for different CSUs

Channel Service Unit (CSU)

Maximum Cabling Distance

 

 

551A

85 feet (27 m)

 

 

551V

85 feet (27 m)

 

 

551V EFS/R

755 feet (199.7 m)

 

 

EFS T1

755 feet (199.7 m)

 

 

 

 

5.For standard reliability systems, refer to Y-cable to cross-connect the TN780 and “CLOCK” end connections to the Stratum 3 clock connections on the cross-connect module.

6.For high or critical reliability systems, refer to table below to cross-connect the TN780 and “CLOCK” end connections to the Stratum 3 clock connections on the cross-connect module.

Table 20.

Y-cable clock-end cross-connects for reliability

 

 

 

 

 

 

 

To Y-cable clock end

 

To Y-cable clock end

 

 

 

 

From Stratum 3 Clock

(primary)

 

 

 

(secondary)

 

 

Lead

 

Lead Color/

Lead

 

Lead Color/

 

Lead

 

Lead Color/

 

 

 

 

Name

 

Terminal

Name

 

Terminal

 

Name

 

Terminal

 

 

 

 

 

 

 

 

 

 

RREF1

 

W-BL/1

 

 

V-O/43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TREF1

 

BL-W/2

 

 

O-V/44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RREF2

 

W-O/3

 

 

 

 

 

 

V-O/43

 

 

 

 

 

 

 

 

 

 

TREF2

 

O-W/4

 

 

 

 

 

 

O-V/44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

555-233-116

Issue 4 October 2002 167

Page 167
Image 167
Avaya 555-233-116 manual Stratum 3 clock wiring installation procedure, BL/1, BL-W/2