Auxiliary power supplies
555-233-116
34 Issue 4 October 2002
Figure 3. 1145B/1146 mounting arrangement
1. Wall mounting plate
2. Optional battery (1149B shown)
3. 1146 power distribution unit
4. 1145B power unit
5. Power cable
6. Unswitched outlet (120 VAC, 20 A or 230
VAC, 15 A)
7. Battery backup switch setting
pcdf1145 KLC 030100
1
2
3
4
6
1149 Battery
1145 Power Unit On Battery Reserve
Charging Battery
Output Power On
1146 Power Distribution Unit
51-32
1-8 7