Extenders for 2-wire DCP endpoints

Table 10. Pin-out for 2-wire DCP endpoints

Pin Number

Function

 

1

not used by 2-wire DCP endpoints

 

 

 

2

not used by 2-wire DCP endpoints

 

 

 

3

not used by 2-wire DCP endpoints

 

 

 

4

DCP signal transmission

 

 

 

5

DCP signal transmission

 

 

 

6

not used by 2-wire DCP endpoints

 

 

 

7

auxiliary power -48 VDC (if needed)

 

 

 

8

auxiliary power ground (if needed)

 

 

 

Figure 7 shows a workstation connecting to a data adapter. The line side of the adapter connects to the TN2181 digital line 2-wire circuit pack through the main distribution frame (MDF) (to the system cabinet).

2

 

1

5

 

 

 

 

 

 

 

Phone

 

 

 

5

4

7

 

 

Line

 

 

I/O

6

3

 

itdata RBP 032896

 

 

 

 

 

 

 

 

 

 

 

1.

103A or modular wall jack

5.

4-wire modular cord

2.

2-wire endpoint

6.

Serial data cable

3.

Data terminal (serial data)

7.

To TN2181 digital line circuit pack

4.

Data adapter (such as an 8400B+)

 

 

 

 

Figure 7. Typical connections to a 2-wire DCP workstation

44 Issue 4 October 2002

555-233-116

Page 44
Image 44
Avaya 555-233-116 manual Typical connections to a 2-wire DCP workstation