Avaya 555-233-116 manual Configuring the ExpressRoute 1000 data module, 128, + 2 + 16 =

Models: 555-233-116

1 246
Download 246 pages 48.27 Kb
Page 94
Image 94

Data modules and asynchronous data units

Table 12. Codes for disabling default settings of the 8400B data module

Default setting

Disabling code

Disable Data Metering Feature

16

 

 

Immediate Speakerphone Activation

32

 

 

Automatic Speakerphone Activation

64

 

 

Disable Busyout During Local Loopback Test

128

Continued on next page

Proceed as follows.

1.Calculate an option-selection value using Table 12, ‘‘Codes for disabling default settings of the 8400B data module’’. Add up the disabling codes for all options that you wish to disable.

For example, if you turned off With Telephone, US Companding, Disable Data Metering Feature, the selection code would be:

1 + 2 + 16 = 19

2.Check the current data-module setting by entering ATS24?.

3.If the current value does not match the selection value you calculated, enter ATS24=nnn, where nnn is the selection value you calculated.

Configuring the ExpressRoute 1000 data module

You can substitute an ExpressRoute 1000 data module for the 8400B data module. Both DCP and ISDN-BRI connections are possible. Figure 18 shows typical connections.

! CAUTION:

In DC-powered cabinet installations, a 105C Isolator adapter is required when connecting equipment to a data module.

94 Issue 4 October 2002

555-233-116

Page 94
Image 94