DS1/T1 CPE loopback jack

ConditionSolution

The service provider successfully loop tested the span, up to the smart jack.

The wiring between the loopback jack and the smart jack is suspect. Test, and make repairs, as needed.

You cannot locate and repair the problem in the time available and must terminate the test.

The test will not terminate normally in the absence of a good framing signal. You have to reset the circuit pack. Enter reset board UUCSS, where UU is the cabinet number, C is the carrier letter, and SS is the slot number of the DS1 board.

NOTE:

If you have a G700 Media Gateway, substitute XXXVS for UUCSS in the above command, where XXX is the administered number of the G700 (for example, 002), and VS is the slot number on the G700 of the Media Module (for example, V3). The V is not a variable and needs to be included in the command exactly where shown. A sample address for a DS1 circuit pack on a G700 Media Gateway might look like this: 002V3.

The test terminated normally.

Proceed with ‘‘Restoring DS1 administration’’.

Restoring DS1 administration

NOTE:

If you have a G700 Media Gateway, substitute XXXVS for UUCSS in the following command, where XXX is the administered number of the G700 (for example, 002), and VS is the slot number on the G700 of the Media Module (for example, V3). The V is not a variable and needs to be included in the command exactly where shown. A sample address for a DS1 circuit pack on a G700 Media Gateway might look like this: 002V3.

1.At the management terminal, open the DS1 administration form. Enter change ds1 UUCSS, where UU is the cabinet number, C is the carrier letter, and SS is the slot number of the DS1 board.

2.Change to page 2 of the DS1 administration form.

3.Change the value of the TX LBO field to the original value that you wrote down when you were ‘‘Administering the DS1 for the test’’ on page 138.

4.Press ENTER to make the changes, CANCEL to quit without changes.

142 Issue 4 October 2002

555-233-116

Page 142
Image 142
Avaya 555-233-116 manual Restoring DS1 administration, ConditionSolution