Property management system (PMS)
555-233-116
226 Issue 4 October 2002
Figure 63. Connections to an asynchronous data unit
Connecting a terminal and/or journal printer
You can connect customer data terminals, host computers, and/or an optiona l
journal printer in either of two ways.

Using data modules

1. Configure printer or terminal in accordance w ith the recommendations in
the vendors documentation.
2. Configure the data module for the printer or terminal, using the instru ctions
in Chapter 4, ‘‘Data modules and asynchronous data units’’.
3. Identify the port associated with the data unit or data mod ule using the
Data Module Form (see ‘‘Administer the data module s’’ on page 95).
1. Z3A1 or Z3A2 ADU
2. 4-pair li ne cord
3. 103A or modular wall jack
4. Analog telephone
5. Satellit e site or adapter location
6. Station s ide blue or white field
7. System si de
8. Data module
9. TXT
10. TXR
11. PX T
12. PXR
13. Tip
14. Ring
15. To analog line circuit pack
16. To data line circuit pack
17. 25-pin RS- 232-D connector (male)
18. Main distr ibution frame
2
2
3
910
10 11
11 12
12
6
8
14 15
LINE V.35
POWER
RS-366/RS-232
9
13
7
0002
_
1RBP 062596