DS1/T1 CPE loopback jack
555-233-116
154 Issue 4 October 2002
Figure 33. Network interface at dumb block with repeater line to fiber MUX for an
MM710 multi-media module
You are responsible for finding and correcting problems in the customer wiring
(section 1 and the loopback cable portion of section 2). Th e DS1 service provider
is responsible for finding and correcting problem s in the majority of section 2.
1. Span section 1
2. Span section 2
3. G7 00 Media Gateway
4. E1/T1 port on an MM710
multi-media module
5. RJ-48 to ne twork interface (up to 1000 ft. [305 m])
6. Loopbac k jack
7. Dumb blo ck (demarcation point)
8. Repeater
9. Fiber mu ltiplexer (MUX)
10. Central office