Multimedia communications products: MMCX, MMCH,

ESM

1.Port B Y-cable connector to a TN787 multimedia interface (MMI) circuit pack

2.Port A Y-cable connector to a TN2207 PRI circuit pack

3.25-pair Y-cable

4.357A adapter

5.D8W cord connected to 357A adapter S/B port 8

6.Expansion service module (ESM)

7.Port B on compatible primary rate interface (PRI) card

Figure 62. Typical multimedia call handling ESM connections

ESM installation

Use the following procedure and Figure 62 to connect to the ESM equipment:

1.Install the TN2207 primary rate interface (PRI) circuit pack and the TN787F/G/H/J/K multimedia interface (MMI) circuit pack in the port carrier.

2.Record the circuit pack locations.

3.Connect the ESM Y-cable as shown.

Administration

1.Enter list configuration all, and a list of the installed carriers, circuit packs, and ports appears.

2.Record the location (board number) of the new circuit packs and verify that all other required circuit packs (refer to ‘‘ESM installation’’) are present.

3.Enter add DS1 xxxxx, (where xxxxx is the location of the TN2207 PRI circuit pack recorded in step 2), and the DS1 circuit pack administration form appears.

4.Set the Name: field to ESM DS1

5.Set the Bit Rate: field to 2.048

6.Set the Line Coding: field to hdb3

7.Set the Signaling Mode: field to isdn-pri

8.Set the Connect: field to pbx

222 Issue 4 October 2002

555-233-116

Page 222
Image 222