DEFINITY INADS

Administration

NOTE:

Add 2 pauses in front of the dial string when using cut-through trunks. Pauses are not required if using ARS.

1.Type change system-parameters maintenance and press Enter.

2.For high reliability systems, in the see interchange: field, type daily and press Enter. This is done in case 1 of the connections between the 2 TN1648B circuit packs is down. This assures that within 24 hours the working connection is available to report alarms.

3.Type add station number or next and press Enter.

4.In the Type field, enter 500 (rotary analog telephone).

5.In the Port field, enter the port number for this line.

6.For high reliability systems, repeat the above steps for the second analog line. Administer the 2 stations as part of a TEG (terminating extension group).

a.Type add term-ext-group number or next and press Enter.

b.In the Group Extension field, enter the TEG extension number.

c.In the Coverage Path field, enter the coverage path number.

d.Enter the Group Member Assignment station numbers.

e.Press Enter when finished.

Partner installation

The PARTNER system connects the INADS port to an outgoing central office (CO) line and is programmed to seize the outside line when INADS seizes an inside PARTNER station line.

There are 2 types of PARTNER platforms:

PARTNER Atlas platforms with U.S. firmware and a wide input power supply (WIPS) that allows a universal power supply. The Spain platform conforms to the United States/Atlas platform

European platforms that focus on eastern Europe and the United Kingdom

The installation procedure describes the 2 types of PARTNER platforms with or without power fail transfer.

555-233-116

Issue 4 October 2002 181