Hoshizaki KM-1300SWH3 IV. Service Diagnosis 1. No Ice Production, Problem, Possible Cause, Remedy

Models: KM-1300SRH3 KM-1300SWH KM-1300SRH KM-1300SAH KM-1300SWH3 KM-1300SAH3

1 69
Download 69 pages 21.22 Kb
Page 43
Image 43

IV. Service Diagnosis

1. No Ice Production

Problem

Possible Cause

 

 

Remedy

 

 

 

 

 

 

 

[1] The icemaker will not

a)

Power Supply

1.

OFF position.

1.

Move to ON position.

start.

 

 

 

 

 

 

 

 

2.

Loose connection.

2.

Tighten.

 

 

 

 

 

 

 

 

 

 

3.

Bad contacts.

3.

Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

 

 

4.

Voltage too high.

4.

Check and get

 

 

 

 

 

 

recommended voltage.

 

b)

Fuse (Inside fused

1.

Blown.

1.

Check for short circuit and

 

 

disconnect, if any)

 

 

 

replace.

 

 

 

 

 

 

 

 

c)

Control Switch

1.

OFF position.

1.

Move to ICE position.

 

 

 

 

 

 

 

 

 

 

2.

Bad contacts.

2.

Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

d)

Bin Control Thermostat

1.

Tripped with bin filled with

1.

Remove ice.

 

 

 

 

ice.

 

 

 

 

 

 

 

 

 

 

 

 

2.

Ambient temperature too

2.

Increase ambient

 

 

 

 

cool.

 

temperature.

 

 

 

 

 

 

 

 

 

 

3.

Set too warm.

3.

See "II.2.[d] Controls and

 

 

 

 

 

 

Adjustments, 6) Bin

 

 

 

 

 

 

Control."

 

 

 

 

 

 

 

 

 

 

4.

Bulb out of position.

4.

Place in position.

 

 

 

 

 

 

 

 

 

 

5.

Bad contacts or leaks in

5.

Check for continuity and

 

 

 

 

bulb.

 

replace.

 

 

 

 

 

 

 

 

e)

High Pressure Control

1.

Bad contacts.

1.

Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

f)

Transformer

1.

Thermal fuse blown or coil

1.

Replace.

 

 

 

 

winding opened.

 

 

 

 

 

 

 

 

 

 

g)

Wiring to Controller

1.

Loose connections or

1.

Check for continuity and

 

 

Board

 

open.

 

replace.

 

 

 

 

 

 

 

 

h)

Thermistor

1.

Leads short-circuit or open

1.

See "II.2.[d] Controls and

 

 

 

 

and high temperature

 

Adjustments, 1) Defrost

 

 

 

 

safety operates.

 

Control."

 

 

 

 

 

 

 

 

i)

Hot Gas Solenoid

1.

Continues to open in

1.

Check for power off in

 

 

Valve

 

freeze cycle and high

 

freeze cycle and replace.

 

 

 

 

temperature safety

 

 

 

 

 

 

operates.

 

 

43

Page 43
Image 43
Hoshizaki KM-1300SWH3, KM-1300SAH3, KM-1300SRH IV. Service Diagnosis 1. No Ice Production, Problem, Possible Cause, Remedy