3. TIMING CHART
When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermistor Temp. exceeds t1.
*
*
*3
*4
If Float Sw. is OFF
Hi Temp Mid Temp Lo Temp Too Lo Temp
Time Up (60 sec)
Control
Sw. in
ICE
Bin Thermo- stat ON
Pressure
Sw. ON
Overheat
Protect
Reset
Min. | Max. | Max. |
2 min | 6 min | 6 min |
Max. 20 min
From Defrost Cycle
To Defrost Cycle
Normal Too Hi Temp Lo Water
Max. Min.
60 min 5 min
*NOTE: The icemaker does not complete a defrost cycle in the first 2 or 3 minutes. See “II. 2. [d] CONTROLS AND ADJUSTMENTS.”