Hoshizaki KML-200MAE Timing Chart, If Float Sw. is OFF, From Defrost Cycle To Defrost Cycle

Models: KML-200MWE KML-200MAE

1 51
Download 51 pages 29.81 Kb
Page 24
Image 24
3. TIMING CHART

3. TIMING CHART

When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermistor Temp. exceeds t1.

*

*

*3

(KM-1200MAE/SAE)

*4

(KM-1200MRE/SRE, KM-2000SRE3)

If Float Sw. is OFF

Hi Temp Mid Temp Lo Temp Too Lo Temp

Time Up (60 sec)

Control

Sw. in

ICE

Bin Thermo- stat ON

Pressure

Sw. ON

Overheat

Protect

Reset

Min.

Max.

Max.

2 min

6 min

6 min

Max. 20 min

From Defrost Cycle

To Defrost Cycle

Normal Too Hi Temp Lo Water

Max. Min.

60 min 5 min

*NOTE: The icemaker does not complete a defrost cycle in the first 2 or 3 minutes. See “II. 2. [d] CONTROLS AND ADJUSTMENTS.”

24

Page 24
Image 24
Hoshizaki KML-200MAE, KML-200MWE service manual Timing Chart, If Float Sw. is OFF, From Defrost Cycle To Defrost Cycle