2. BRAZING
WARNING
1.Refrigerant R22 itself is not flammable, explosive or poisonous. How- ever, when exposed to an open flame, R22 creates Phosgene gas, hazardous in large amounts.
2.Always recover the refrigerant and store it in an approved container. Do not discharge the refrigerant into the atmosphere.
3.Do not use silver alloy or copper alloy containing Arsenic.
Note: All
3.REMOVAL AND REPLACEMENT OF COMPRESSOR IMPORTANT
Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made.
Note: When replacing a Compressor with a defective winding, be sure to install the Start Capacitor, Run Capacitor and Start Relay supplied with the replacement Compressor.
1)Turn off the power supply.
2)Remove the panels.
3)Recover the refrigerant and store it in an approved container.
4)Remove the terminal Cover on the Compressor, and disconnect the Compressor Wiring.
5)Remove the Discharge and Suction Pipes using brazing equipment.
6)Remove the
34