4.PERFORMANCE DATA
[a]
APPROXIMATE
ICE PRODUCTION
PER 24 HR.
lbs./day (kg./day)
APPROXIMATE ELECTRIC CONSUMPTION
watts
APPROXIMATE WATER CONSUMPTION PER 24 HR.
gal./day (m3/day)
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
PSIG
SUCTION PRESSURE
PSIG (kg/cm2G)
TOTAL HEAT OF REJECTION
AMBIENT |
| WATER TEMP. ( °F/°C ) |
| ||
TEMP. ( °F/°C ) | 50/10 |
| 70/21 | 90/32 | |
|
|
|
|
| |
70/21 | *250 (113) |
| 240 (109) | 220 (100) | |
80/27 | 241 (109) |
| 226 (103) | 210 ( | 95) |
90/32 | 230 (104) |
| *214 ( 97) | 199 ( | 90) |
100/38 | 218 ( 99) |
| 203 ( 92) | 187 ( | 85) |
|
|
|
|
|
|
70/21 | *770 |
| 776 | 801 |
|
80/27 | 774 |
| 784 | 818 |
|
90/32 | 776 |
| *790 | 821 |
|
100/38 | 787 |
| 797 | 850 |
|
|
|
|
|
| |
70/21 | *81 ( 0.31 ) |
| 73 ( 0.28 ) | 63 ( 0.24 ) | |
80/27 | 75 ( 0.28 ) |
| 62 ( 0.24 ) | 54 ( 0.20 ) | |
90/32 | 73 ( 0.28 ) |
| *54 ( 0.20 ) | 44 ( 0.17 ) | |
100/38 | 71 ( 0.27 ) |
| 51 ( 0.19 ) | *36 ( 0.14 ) | |
|
|
|
|
|
|
70/21 | *20 |
| 21 | 28 |
|
80/27 | 21 |
| 23 | 32 |
|
90/32 | 21 |
| *24 | 32 |
|
100/38 | 24 |
| 26 | *40 |
|
|
|
|
|
|
|
70/21 | *2.5 |
| 2 | 2 |
|
80/27 | 2 |
| 2 | 2 |
|
90/32 | 2 |
| *2 | 2 |
|
100/38 | 3 |
| 2 | *2 |
|
|
|
|
|
|
|
70/21 | *260 |
| 268 | 276 |
|
80/27 | 266 |
| 278 | 284 |
|
90/32 | 268 |
| *286 | 293 |
|
100/38 | 268 |
| 288 | *300 |
|
|
|
|
|
|
|
70/21 | *25 |
| 26 | 36 |
|
80/27 | 26 |
| 28 | 42 |
|
90/32 | 26 |
| *30 | 42 |
|
100/38 | 31 |
| 33 | *53 |
|
|
|
|
|
|
|
5980 Btu/h [AT 90°F (32°C) / WT 70°F (21°C)]
Note: Pressure data is recorded first 5 minutes in freezing cycle.
The data without *marks should be used for reference.
* We reserve the right to make changes in specifications and design without prior notice.
26