Hoshizaki KML-200MWE, KML-200MAE service manual Removal And Replacement Of Fan Motor

Models: KML-200MWE KML-200MAE

1 51
Download 51 pages 29.81 Kb
Page 43
Image 43

10)Secure the insulation using the Plastic Cable Ties.

11)Connect the Thermistor leads through the bushing of the Control Box to the K3 Connector on the Controller Board.

Note: Do not cut the leads of the Thermistor while installing it.

12)Replace the Control Box Cover and the panels in their correct positions.

13)Turn on the power supply.

11. REMOVAL AND REPLACEMENT OF FAN MOTOR

Note: When replacing a Fan Motor with defective winding, it is recommended that a new capacitor be installed.

1)Turn off the power supply.

2)Remove the panels.

3)Remove the closed end connectors from the Fan Motor leads.

4)Remove the Fan Motor Bracket and Fan Motor.

5)Remove the wiring connectors from the Pump Motor leads.

6)Install the new Fan Motor, and replace the removed parts in the reverse order of which they were removed.

7)Replace the panels in their correct positions.

8)Turn on the power supply.

43

Page 43
Image 43
Hoshizaki KML-200MWE, KML-200MAE service manual Removal And Replacement Of Fan Motor