3-8 CHAPTER 3: CONFIGURING THE EDGE ROUTER MODULE

Determining the Table 3-1 shows how to determine the carrier configuration source

Configuration

Source

.

 

 

 

Table 3-1 Determining the Carrier Configuration Source

 

 

 

 

 

 

 

DMM DIP

NVRAM DIP

Carrier

 

Hot Swap?

Configuration*

Switch

Configuration Source

 

Yes

Disable

ON or OFF

DMM passes the old

 

 

 

 

configuration settings to the

 

 

 

 

new carrier.

 

 

Enable

ON

NVRAM settings

 

 

 

OFF

DIP switch settings

 

No

Disable

ON

NVRAM settings

 

 

 

OFF

Default settings

 

 

Enable

ON

NVRAM settings

 

 

 

OFF

DIP switch settings

 

 

 

 

 

*Use the SHOW DEVICE command to view the DIP configuration setting. Use the SET DEVICE DIP_CONFIGURATION command to change the DIP configuration setting.

If the carrier does not have configuration settings stored in NVRAM, it uses default settings.

If the DMM detects a problem with the NVRAM configuration, it forces the carrier to use default settings. For example, if you install the carrier with ports assigned to Ethernet_8 into an ONcore hub model that does not support Ethernet_8. If the configuration problem is port level, the DMM forces only the affected ports to use default settings.

‡ The DMM must be fully initialized when you install the carrier module.

Selecting a Network The Edge Router engine connects to an Ethernet network through a backplane port on the ONcore carrier. A base engine installed in ONcore carrier engine bay 1 uses carrier backplane port 1. A base engine installed in ONcore carrier engine bay 2 uses carrier backplane port 5.

You can assign a carrier backplane port to:

One of eight Ethernet backplane networks

One of four Isolated backplane networks

For details on backplane networks, refer to the ONcore Switching Hub Installation and Operation Guide (Document Number 17-00362-5).

Page 48
Image 48
HP 2103R-CSDI manual DMM DIP Nvram DIP