Reference Information

S-Registers (Conexant)

Register

Function (Conexant)

Range/Units

Default

 

 

 

 

 

S0

Number of rings to

0-255/rings

0

 

 

auto-answer.

 

 

 

 

 

 

 

 

S1

Ring counter.

0-255/rings

0

 

 

 

 

 

 

S2

Escape character.

0-255/ASCII

43

 

 

 

 

 

 

S3

Line termination character.

0-127/ASCII

13

 

 

 

 

 

 

S4

Response formatting

0-127/ASCII

10

(line feed)

 

character.

 

 

 

 

 

 

 

 

S5

Command line editing

0-32/ASCII

8

 

 

character.

 

(backspace)

 

 

 

 

 

S6

Wait time for dial tone.

2-255/sec

2

 

 

 

 

 

 

S7

Wait time for carrier.

1-255/sec

50

 

 

 

 

 

 

S8

Pause time for dial delay

0-255/sec

2

 

 

modifier.

 

 

 

 

 

 

 

 

S10

Carrier loss

1-255/.1 sec

14

(1.4 sec)

 

disconnect time.

 

 

 

 

 

 

 

 

S11

DTMF tone duration.

50-255/.001 sec

95

(95 msec)

 

 

 

 

 

S12

Escape prompt delay.

0-255/.02 sec

50

(1 sec)

 

 

 

 

 

S18

Test timer.

0-255/sec

0

 

 

 

 

 

 

S29

Flash dial modifier time.

0-255/10 msec

70

 

 

 

 

(700 msec)

 

 

 

 

 

S30

Disconnect inactivity timer.

0-255/10 sec

0

 

 

 

 

 

S46

Data compression control.

136 (error

138

 

 

correction

 

 

 

 

w/o compression)

 

 

 

 

or 138 (error

 

 

 

 

correction &

 

 

 

 

compression)

 

 

 

 

 

 

 

S95

Extended result code

 

0

 

 

messages control.

 

 

 

 

 

 

 

 

7–14

Reference Guide