HP 5L (C3941A) manual High Voltage Power Distribution

Models: 5L (C3941A)

1 196
Download 196 pages 56.31 Kb
Page 61
Image 61

A job is received.

The Front Panel Button is pressed.

The printer front door is opened.

N o t e

The printer will not enter SleepMode if there is a printer error.

High Voltage Power Distribution

The High Voltage Power Supply PCA applies an overlap of dc and AC voltage to the primary charging roller and the developing roller. This circuit also applies a positive or negative dc voltage to the transfer charging roller according to the instructions from the CPU on the DC Controller PCA.

This circuit also controls the image density by changing the primary AC voltage and the developing AC bias according to the setting of the print density dial.

High voltage is disabled when the printer’s EP Door is open (i.e., switch SW101 is open).

Functional Overview 5 - 7

Page 61
Image 61
HP 5L (C3941A) manual High Voltage Power Distribution