Control panel message | Description | Recommended action | |
|
|
|
|
BIOS information passed to the MEBx | 1. | Reboot the computer. | |
| resulted in a failure. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
MEBx operation experienced a hardware | 1. | Reboot the computer. | |
| error during communication with ME. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
| |
DIMM1 or XMM1 is not installed. | Make sure there is a memory module in the | ||
proper MEBx execution. |
| black DIMM1 socket and that it is properly | |
|
| seated. |
USB device used for USB key provisioning | 1. | Try a different USB key device for |
will not allow BIOS to update provision file |
| provisioning. |
properly. | 2. | If the error persists, update to the latest |
| ||
|
| BIOS version and ME firmware version. |
| 3. | If the error still persists, replace the |
|
| system board. |
ME firmware is not properly responding to | 1. | Reboot the computer. | |
| BIOS query for version information. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version and ME firmware version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
ME firmware must be updated to match current functionality contained in the system BIOS.
1.Update to the latest ME firmware version.
2.If the error persists and system BIOS has been recently updated, restore previous system BIOS version.
3.If the error still persists, replace the system board.
Provisioning file contained on the USB key has been corrupted or is not a valid version for the current ME firmware.
1.Recreate the provisioning file using third party management console software.
2.If the error persists and system BIOS has been recently updated, restore previous system BIOS version. Otherwise, update the ME firmware version.
3.If the error still persists, replace the system board.