ProCurve

 

 

Figure 1-4. Management Module LEDsTable 1-2. Management Module LEDs

These LEDs are located on the Management Module.

LED

State

Meaning

 

 

 

Auxiliary (green/

Blinking

Indicates the switch is processing a USB command file.

orange) For more

green1

 

information see the

 

 

Management and

On green

The switch has finished processing the USB command file successfully.

Configuration Guide

Blinking

Indicates an error condition.

for your switch.

 

orange2

 

 

Off

Indicates that no USB device has been inserted, or that the inserted USB device

 

 

cannot be recognized, or that no command file can be found on the inserted USB

 

 

device.

 

 

 

DIM

On green

DIM (Dual in-line Memory Module) status is known and fault free.

(green/orange)

Off

DIM status is unknown.

 

 

Blinking

If DIM, Fault, and Self Test LEDs are blinking, DIMM failed self-test.

 

orange1

If DIM and Fault LEDs are blinking, an operational fault has occurred.

 

 

If fast blinking (400ms On and 400ms Off), an operational alert occurred and is

 

 

unresolved.

 

 

 

CF

On green

CF (CompactFlash) status is known and fault free

(green/orange)

Off

CF status is unknown.

 

 

 

 

Blinking

If CF, Fault, and Self Test LEDs are blinking, CompactFlash failed self-test.

 

orange1

If CF and Fault LEDs are blinking, an operational fault has occurred.

 

 

If fast blinking (400ms On and 400ms Off), an operational alert occurred and is

 

 

unresolved (for example, CompactFlash not present).

 

 

 