| Introducing the ProCurve Series 8200zl Switch |
|
| Front of the Switch |
|
|
|
PoE | On green | If any PoE modules are installed. |
(green/orange) | Off | If no PoE modules are installed. |
| Blinking | Internal PoE fault. |
| orange1 | External load fault or denied PoE power. |
| Blinking |
|
| orange2 |
|
Tmp | Off | Switch temperature is normal. |
(green/orange) | Blinking1 | An over temperature condition has been detected. |
| ||
Fan | On green | The cooling fans are operating normally. |
(green/orange) | Blinking | One or more of the cooling fans have failed. The switch Fault LED will be blinking |
| ||
| orange1 | simultaneously. |
Internal Power | On green | A power supply is installed in the position in the back of the switch corresponding |
(green/orange - |
| to the number, and the supply is plugged in to an active AC power source. As |
numbers |
| shipped, the switch has a single power supply in position 1. |
corresponding to | Off | A power supply is not installed in the position corresponding to the number. |
the power supply | ||
positions) | Blinking | The power supply installed in the position corresponding to the number is not |
| ||
| orange1 | plugged in to an active AC power source, or has experienced a fault. The switch |
|
| Fault LED will be blinking simultaneously. |
|
|
|
EPS (1 and 2) | On green | An External Power Supply is connected. |
(green/orange) | Off | No External Power Supply is connected. |
| Blinking | The External Power Supply has a fault, or is connected but not plugged into AC |
| orange1 | power. |
Fabric Modules | On green | A Fabric Module is installed and functioning correctly. |
(1 and 2) | Off | A Fabric Module is not installed or has failed. |
(green/orange) | Blinking | The Fabric Module has a fault. |
| ||
| orange1 | The switch Fault LED will be blinking simultaneously. |
8200zl Series | the Introducing |
Switch | ProCurve |
|
|