Introducing the ProCurve Series 8200zl Switch
Front of the Switch
Switch Modules with Link and Mode LEDs
for each port located on each module
| Figure | ||
| Table | Switch Module LEDs | |
| These LEDs are located on the modules themselves, one pair for each port. | ||
|
|
|
|
LED | State |
| Meaning |
|
|
|
|
Link | On |
| Indicates the port is enabled and receiving a link beat signal (for the |
|
|
| ports), or a strong enough light level (for the |
|
|
| device. |
| Off |
| One of these conditions exists: |
|
|
| • no active network cable is connected to the port |
|
|
| • the port is not receiving link beat or sufficient light |
|
|
| • the port has been disabled through the switch console, the web browser |
|
|
| interface, ProCurve Manager, or other network management tool. |
| Blinking1 |
| The port has failed self test. The switch Fault, Self Test LEDs, and appropriate |
|
|
| module status LEDs will flash simultaneously. |
|
|
| |
Mode | Depending on the mode selected, displays the following: network activity information, whether | ||
| the port is configured for Full Duplex operation, maximum speed operation, or whether PoE | ||
| power is being supplied or not. See “LED Mode Select Button and Indicator LEDs” below for | ||
| more information. | ||
|
|
|
|
1 The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.