Introducing the ProCurve

Series 8200zl Switch

 

 

Introducing the ProCurve Series 8200zl Switch

Back of the Switch

Redundant Power Supply

Load-sharing redundant power supplies (ProCurve Switch zl 875 W Power Supply, J8712A or a ProCurve Switch zl 1500 W Power Supply J8713A) can be installed in the back of the Series 8200zl Switch. To provide redundancy, each power supply should be connected to different AC power sources. Then, if one AC power source fails, the switch will continue to run.

C a u t i o n

The switch redundant power supply is hot swappable, but, as indicated by the

 

caution statement on the power supply, it must be disconnected from AC

 

power before being installed or removed.

 

CAUTION:

 

.Refer to the installation guide for proper power cord selection

 

.Disconnect AC power from the power supply BEFORE installing or

 

removing the supply. Otherwise, damage to the. equipment may result.

 

 

Because the switch can run on a single supply, removing a redundant supply will not interrupt switch operation. However, on the 8212zl one power supply will only supply enough power to run the module slots A-F. Slots G-L will not receive any power unless there are at least two power supplies installed.

When power is restored to a second (or more) power supplies, a system reload or interface module reset may be required to restore operation to slots G-L.

For more information regarding power see the:

ProCurve Switch zl Internal Power Supply Installation Guide.

ProCurve PoE (Power over Ethernet) Devices Planning and Implementation Guide.