Visual Basic (Windows-95)

W_9112_GetOverrunStatus(ByVal card_number As Long, overrunCount As Long) As Long

C/C++ ( DOS)

int _9112_GetOverrunStatus (int card_number, int *overrunCount )

uArgument

card_number : the card number of PCI-9112

overrunCount: number of overrun counts.

uReturn Code

ERR_NoError, ERR_BoardNoInit

uExample

See Demo Program 'AD_DEMO5.C'

5.21 _9112_ContDmaStop

uDescription

This function is used to stop the continuous DMA data transferring.

uSyntax

Visual C++ (Windows-95)

int W_9112_ContDmaStop (int card_number)

Visual Basic (Windows-95)

W_9112_ContDmaStop (ByVal card_number As Long) As Long

C/C++ ( DOS)

int _9112_ContDmaStop (int card_number)

uArgument :

card_number : the card number of PCI-9112

uReturn Code :

ERR_NoError, ERR_BoardNoInit

uExample :

See Demo Program 'AD_DEMO5.C'

58 C/C++ Library