Software Fixes

 

 

Release Notes for 07.8.04

 

 

 

 

 

 

 

 

Bug ID

 

Bug Description

Protocol/

Version

Version

 

 

 

 

Feature

Found

Fixed

 

 

 

 

 

 

 

 

59468

 

If OSPF is configured, the OSPF configuration is

OSPF

 

07.8.02

 

 

 

not displayed in show ip ospf config command

 

 

 

 

 

 

output until the configuration is saved and the

 

 

 

 

 

 

switch is rebooted.

 

 

 

 

 

 

 

 

 

 

 

59698

 

If SSH is configured, a system reload sometimes

SSH

 

07.8.02

 

 

 

occurs due to insufficient stack space.

 

 

 

 

 

 

 

 

 

 

 

59925

 

The incorrect deletion of CAM entries may cause a

System

 

07.8.02

 

 

 

routing switch to reload.

 

 

 

 

 

 

 

 

 

 

 

60117

 

If you enable the VSRP and CPU Protection

VSRP

 

07.8.02

 

 

 

features, when a link flaps, the VSRP forwarding

 

 

 

 

 

 

state is not correctly set. As a result, the CAM for

 

 

 

 

 

 

the master is not updated correctly, resulting in a

 

 

 

 

 

 

Layer 2 packet loop.

 

 

 

 

 

 

 

 

 

 

 

60227

 

When you configure an incorrect speed on a virtual

System

 

07.8.02

 

 

 

interface, the valid physical port is not checked,

 

 

 

 

 

 

resulting in a system reload.

 

 

 

 

 

 

 

 

 

 

 

60249

 

If BGP4 is configured and a BGP update is received

BGP4

 

07.8.02

 

 

 

for an existing prefix, in some cases the BGP route

 

 

 

 

 

 

does not include the BGP tree node. This can

 

 

 

 

 

 

cause the system to reload.

 

 

 

 

 

 

 

 

 

 

 

60330

 

If a large number of VLANs are configured, when

System

 

07.8.02

 

 

 

you remove or add a tagged port from a VLAN, high

 

 

 

 

 

 

CPU utilization occurs.

 

 

 

 

 

 

 

 

 

 

 

60396

 

When a static MAC address is configured on

System

 

07.8.02

 

 

 

multiple ports, the address is not displayed on all

 

 

 

 

 

 

ports in show mac ethernet <slot/port> command

 

 

 

 

 

 

output.

 

 

 

 

 

 

 

 

 

 

 

60401

 

When you configure a username password using all

System

 

07.8.02

 

 

 

numeric characters, it is necessary to re-enter the

 

 

 

 

 

 

service password-encryption command after you

 

 

 

 

 

 

add each password.

 

 

 

 

 

 

To create an MD5 password, use one of the

 

 

 

 

 

 

following commands:

 

 

 

 

 

 

username <username> create-password

 

 

 

 

 

 

<password-string>

 

 

 

 

 

 

username <username> privilege <number>

 

 

 

 

 

 

create-password <password-string>

 

 

 

 

 

 

Both commands generate the same syntax.

 

 

 

 

 

 

username <username> password <number>

 

 

 

 

 

 

<encryptedpassword-string>

 

 

 

 

 

 

Or

 

 

 

 

 

 

username <username> privilege <number>

 

 

 

 

 

 

password <number> <encrypted-password-

 

 

 

 

 

 

string>

 

 

 

 

 

 

 

 

 

 

44