Software Fixes

 

 

Release Notes for 07.8.04

 

 

 

 

 

 

 

 

Bug ID

 

Bug Description

Protocol/

Version

Version

 

 

 

 

Feature

Found

Fixed

 

 

 

 

 

 

 

 

65528

 

Removing a module from a routing switch may

System

 

07.8.03

 

 

 

cause Port Database entries on the module to be

 

 

 

 

 

 

inaccessible, resulting in a system reload.

 

 

 

 

 

 

 

 

 

 

 

66003

 

After a module is removed from a routing switch, a

System

 

07.8.03

 

 

 

syslog message is sometimes generated that lacks

 

 

 

 

 

 

information to sufficiently describe the cause. This

 

 

 

 

 

 

fix provides the following possible causes in the

 

 

 

 

 

 

syslog:

 

 

 

 

 

 

• The module is removed by the user.

 

 

 

 

 

 

• Hardware failure of the module occurred.

 

 

 

 

 

 

• A failure to read Board ID occurred.

 

 

 

 

 

 

 

 

 

 

 

66207

 

When 10 Gigabit Ethernet modules (MSA) are

System

 

07.8.03

 

 

 

installed, entering the debug command to perform

 

 

 

 

 

 

backplane debugging can sometimes cause a

 

 

 

 

 

 

system reload.

 

 

 

 

 

 

 

 

 

 

 

67109

 

If RIPv2 and redistribution are configured and you

RIPv2

 

07.8.03

 

 

 

remove a static route, an incorrect metric instead of

 

 

 

 

 

 

a poison metric of 16 is sent out.

 

 

 

 

 

 

 

 

 

 

 

67172

 

An Inter Process Communication-related message

System

 

07.8.03

 

 

 

may cause a system reload.

 

 

 

 

 

 

 

 

 

 

 

67848

 

If you configure an IP MTU, the show ip interface

IP Stack

 

07.8.03

 

 

 

<slot/port> command does not correctly display the

 

 

 

 

 

 

configured IP MTU value.

 

 

 

 

 

 

 

 

 

 

 

67854

 

If you configure an IP MTU and later modify the

IP Stack

 

07.8.03

 

 

 

MTU value, the new value is not updated.

 

 

 

 

 

 

 

 

 

 

 

68140

 

If you configure OSPF and enable traps, OSPF

OSPF

 

07.8.03

 

 

 

neighbor state changes are not logged if the

 

 

 

 

 

 

interface is not the designated router (DR).

 

 

 

 

 

 

 

 

 

 

 

68295

 

The configuration of time zones in 30-second

SNTP

 

07.8.03

 

 

 

increments is not supported on the Simple Network

 

 

 

 

 

 

Time Protocol (SNTP) clock.

 

 

 

 

 

 

 

 

 

 

 

68645

 

When you download an image via INM with the

System

 

07.8.03

 

 

 

option to save the configuration on a routing switch,

 

 

 

 

 

 

a log message is generated with an invalid user

 

 

 

 

 

 

name and remote IP address.

 

 

 

 

 

 

 

 

 

 

 

69093

 

When you run diagnostics on a routing switch by

System

 

07.8.03

 

 

 

using the dm diag command, a system reload may

 

 

 

 

 

 

occur.

 

 

 

 

 

 

 

 

 

 

 

69140

 

If you configure a single spanning tree, if the

Spanning Tree

 

07.8.03

 

 

 

configuration has a large number of VLANs (several

 

 

 

 

 

 

hundred), a system reload may occur when you

 

 

 

 

 

 

enter the show span command.

 

 

 

 

 

 

 

 

 

 

 

 

 

07.8.03a

 

 

 

 

 

 

 

 

 

 