Boot Code Requirements for ProCurve Software

 

 

Release Notes for 07.8.04

 

Table 5: Boot Code Requirements

 

 

 

 

 

Routing

Modules

Software Image

Minimum Boot Code

Switch

 

 

 

Required

 

 

 

 

 

ProCurve 9304M

With one of the following

HPR06636.bin

2

M1B07108.bin or greater

ProCurve 9308M

M11 modules (without

 

recommended

 

 

 

Redundant Management):

 

 

 

 

J4141A 10/100

 

 

 

 

J4144A Gigabit SX

 

 

 

 

J4146A Gigabit 4LX/4SX

 

 

 

 

 

 

 

ProCurve 9304M

With any one or two of the

For M2, M4, and EP

For M2, M4, and EP

ProCurve 9308M

following Redundant

Redundant Management

Redundant Management

ProCurve 9315M

Management: modules

modules:

 

modules:

 

2

- H2R07803.bin

- M2B07605.bin or greater

 

J4846A Gigabit SX (M2)

 

 

 

 

J4845A Gigabit LX2 (M2)

 

 

For T-Flow Redundant

 

J4847A 0-Port2(M2)

For T-Flow Redundant

Management modules:

 

J4857A Mini-GBIC (M4)

Management modules:

- M2B07605.bin (all MP

 

J4885A EP

- TSP07801d.bin

images)

 

J4879A T-Flow

 

 

- VSB07100.bin (VSM code)

 

 

 

 

 

 

 

 

10 Gigabit Ethernet (10GE)

The Field-Programmable

10 Gigabit Ethernet modules

 

Modules

Gate Arrays (FPGAs) in 10

do not use any of the boot

 

Note: To upgrade FPGA

Gigabit Ethernet Modules

images listed above.

 

use the following software.

 

 

code, refer to “Upgrading

 

 

 

 

 

 

the FPGA on a 10 Gigabit

J4891A FPGA:

 

 

Ethernet Module” on

rxbmgr.bin – version 80,

 

 

page 11.

revision 6

 

 

 

 

rxpp.bin – version 81,

 

 

 

revision 16

 

 

 

 

txaccum.bin – version 82,

 

 

 

revision 6

 

 

 

 

txpp.bin – version 83,

 

 

 

revision 13

 

 

 

 

ageram.bin – version 84,

 

 

 

revision 4

 

 

 

 

J8174A FPGA:

 

 

 

xpp.bin – version 88, revision

 

 

 

37

 

 

 

 

xtm.bin – version 89, revision

 

 

 

39

 

 

 

 

Note: To determine the

 

 

 

FPGA versions running on a

 

 

 

10GE module, enter show

 

 

 

flash. The version

 

 

 

information is listed

 

 

 

separately for each 10

 

 

 

Gigabit Ethernet module in

 

 

 

the chassis.

 

 

 

 

 

 

 

ProCurve 6308M-

HPR06636.bin

2

M1B07108.bin or greater

SX

 

 

recommended

 

 

 

 

 

 

 

 

6