HP B6191-90029 Monitor Configuration File Entries, Setting Values Description, Eventnum must be a

Models: B6191-90029

1 140
Download 140 pages 5.09 Kb
Page 101
Image 101

Hardware Monitor Configuration Files

Monitor-Specific and Global Configuration Files

Table 5-1 lists the common fields used to define monitor configuration settings. In addition to the common parameters, some monitors include other parameters in their configuration file. Any additional configuration parameters used by each monitor are listed in the monitor descriptions in the data sheets for the hardware event monitors available on the Web at http://docs.hp.com/hpux/onlinedocs/diag/ems/emd_summ.htm.

NOTE

An HP-UX man page is available for each monitor. To access the man page, type (where

 

monitorname is the executable file listed in the data sheet): man monitorname

 

 

 

 

 

Table 5-1

Monitor Configuration File Entries

 

 

 

 

 

 

Setting

Values

Description

 

 

 

 

 

SEVERITY_ACTION

Valid severity values

Defines whether the

 

<severity> <action>

are:

monitor should report or

 

 

 

CRITICAL

ignore events for the

 

 

 

indicated severity level.

 

 

 

SERIOUS

 

 

 

 

 

 

 

MAJOR_WARNING

 

 

 

 

MINOR_WARNING

 

 

 

 

INFORMATIONAL

 

 

 

 

Valid action values are:

 

 

 

 

NOTIFY

 

 

 

 

IGNORE

 

 

 

 

 

 

DEFINE_EVENT

event_num must be a

Identifies an event, the

 

<event_num><severity>

positive integer less than

severity to be applied to

 

<action>

 

65536 for

the event, and the action

 

 

 

monitor-defined events,

the monitor should take

 

 

 

or larger than 100000 for

when the event occurs.

 

 

 

SCSI default events

An action of DEFAULT

 

 

 

Valid severity values

 

 

 

indicates that the value

 

 

 

are:

specified in the

 

 

 

CRITICAL

SEVERITY_ACTION

 

 

 

definition for the

 

 

 

SERIOUS

 

 

 

specified severity should

 

 

 

MAJOR_WARNING

 

 

 

be used.

 

 

 

MINOR_WARNING

 

 

 

 

 

 

 

INFORMATIONAL

 

 

 

 

Valid action values are:

 

 

 

 

NOTIFY

 

 

 

 

IGNORE

 

 

 

 

DEFAULT

 

 

 

 

 

 

POLL_INTERVAL <interval>

interval must be a

Defines how often the

 

 

 

positive integer

monitor should poll the

 

 

 

indicating number of

device to determine if an

 

 

 

minutes to wait between

event has occurred.

 

 

 

polls

 

 

 

 

 

 

 

Chapter 5

101

Page 101
Image 101
HP B6191-90029 manual Monitor Configuration File Entries, Setting Values Description, Eventnum must be a, Interval must be a