Hardware Monitor Configuration Files

Monitor-Specific and Global Configuration Files

DEFINE_EVENT

100065

 

CRITICAL

DEFAULT #

msg num 104

#

[ 09 01

06 --

]

----WR-O--

Tracking servo failure.

#

---------------------------------------------------------

 

 

 

 

DEFINE_EVENT

100166

 

CRITICAL

DEFAULT #

msg num 105

#

[ 09 02

06 --

]

----WR-O--

Focus servo

failure.

DEFINE_EVENT

100266

 

CRITICAL

DEFAULT #

msg num 106

#

[ 09 03

04 --

]

----WR-O--

Spindle servo failure.

#

---------------------------------------------------------

 

 

 

 

DEFINE_EVENT

100067

 

CRITICAL

DEFAULT #

msg num 107

#

[ 42 00

06 --

] D---------

Power-on or

self-test failure.

#

---------------------------------------------------------

 

 

 

 

DEFINE_EVENT

100068

 

CRITICAL

DEFAULT #

msg num 108

#

[ 40 00

06 --

] D---------

Ram failure

-- should use 40 nn.

#

---------------------------------------------------------

 

 

 

 

DEFINE_EVENT

100069

 

CRITICAL

DEFAULT #

msg num 109

#

[ 40 00

06 --

] D---------

Ram failure

-- should use 40 nn.

#

---------------------------------------------------------

 

 

 

 

DEFINE_EVENT

100170

 

CRITICAL

DEFAULT #

msg num 110

#[ 47 00 06 -- ] DTLPWRSOMC Scsi parity error.

DEFINE_EVENT

100270

CRITICAL

DEFAULT

#

msg num

110

#

[ 47 00

0b --

]

 

 

 

 

#

---------------------------------------------------------

 

 

 

 

 

DEFINE_EVENT

100171

CRITICAL

DEFAULT

#

msg num

111

#[ 46 00 0b -- ] DTLPWRSOMC Unsuccessful soft reset.

DEFINE_EVENT 100271

CRITICAL

DEFAULT

#

msg num

111

#

[ -- --

0b --

]

 

 

 

 

#

---------------------------------------------------------

 

 

 

 

 

DEFINE_EVENT 100172

CRITICAL

DEFAULT

#

msg num

112

#[ 04 00 02 -- ] DTLPWRSOMC Logical unit not ready, cause not reportable.

DEFINE_EVENT 100272 CRITICAL

DEFAULT # msg num 113

#[ 04 01 02 -- ] DTLPWRSOMC Logical unit is in process of becoming ready.

DEFINE_EVENT 100372 CRITICAL

DEFAULT # msg num 115

#[ 04 02 02 -- ] DTLPWRSOMC Logical unit not ready, init command required.

DEFINE_EVENT 100472 CRITICAL

DEFAULT # msg num 116

#[ 04 03 02 -- ] DTLPWRSOMC Logical unit not ready, manual fix required.

DEFINE_EVENT 100572 CRITICAL

DEFAULT # msg num 120

#[ 08 01 04 -- ] DTL-WRSOMC Logical unit communication time-out.

DEFINE_EVENT

100672

CRITICAL

DEFAULT

#

msg num

183

#

[ 25 01

05 -- ]

 

 

 

 

 

DEFINE_EVENT

100772

CRITICAL

DEFAULT

#

msg num

117

#[ 29 00 06 -- ] DTLPWRSOMC Power on, reset, or bus device reset occurred.

DEFINE_EVENT

100872

CRITICAL

DEFAULT # msg num 112

#

[ 48 00

0b --

]

 

DEFINE_EVENT

100972

CRITICAL

DEFAULT # msg num 182

#

[ 5d 00

01 --

]

 

DEFINE_EVENT

101072

CRITICAL

DEFAULT # msg num 165

#

[ -- --

02 --

]

 

#

---------------------------------------------------------

 

 

DEFINE_EVENT

100173

CRITICAL

DEFAULT # msg num 118

Chapter 5

111

Page 111
Image 111
HP B6191-90029 manual Defineevent 100272 Critical, Defineevent 100372 Critical, Defineevent 100472 Critical