Hardware Monitor Configuration Files

Monitor-Specific and Global Configuration Files

#

[ 04 00

05 -- ]

 

DEFINE_EVENT

100273 CRITICAL

DEFAULT # msg num 118

#[ 08 00 04 -- ] DTL-WRSOMC Logical unit communication failure.

DEFINE_EVENT

100373

CRITICAL

DEFAULT

#

msg num 114

#

[ 41 00

04 --

] D---------

Data path

failure --

should use 40 nn.

#

---------------------------------------------------------

 

 

 

 

 

DEFINE_EVENT

100074

CRITICAL

DEFAULT

#

msg num 119

#[ 05 00 04 -- ] DTL-WRSOMC Logical unit does not respond to selection.

#---------------------------------------------------------

DEFINE_EVENT 100075 CRITICAL

DEFAULT # msg num 121

#[ 08 02 04 -- ] DTL-WRSOMC Logical unit communication parity error.

#---------------------------------------------------------

DEFINE_EVENT

100176

CRITICAL

DEFAULT

#

msg num

187

#

[ 00 06

0b -- ]

 

 

 

 

 

DEFINE_EVENT

100276

CRITICAL

DEFAULT

#

msg num

122

#[ 1a 00 05 -- ] DTLPWRSOMC Parameter list length error.

DEFINE_EVENT 100376 CRITICAL

DEFAULT # msg num 123

#[ 20 00 05 -- ] DTLPWRSOMC Invalid command operation code.

DEFINE_EVENT 100476 CRITICAL

DEFAULT # msg num 123

#[ 21 00 05 -- ] DT--WR-OM- Logical block address out of range.

DEFINE_EVENT

100576

 

CRITICAL

DEFAULT # msg

num 162

#

[

21

01

05 --

]

--------

M- Invalid

element

address.

DEFINE_EVENT

100676

 

CRITICAL

DEFAULT

#

msg

num

125

#

[

22

00

05 --

]

D---------

Illegal

function for device type

DEFINE_EVENT

100776

 

CRITICAL

DEFAULT

#

msg num

126

#[ 24 00 05 -- ] DTLPWRSOMC Invalid field in cdb. Check fld ptr in sense.

DEFINE_EVENT 100876 CRITICAL

DEFAULT # msg num 127

#[ 25 00 05 -- ] DTLPWRSOMC Logical unit not supported.

DEFINE_EVENT

100976

CRITICAL

DEFAULT

# msg

num 128

 

#

[ 26

00

05

-- ] DTLPWRSOMC Invalid field in param list -- chk

fld ptr.

DEFINE_EVENT

101076

CRITICAL

DEFAULT

# msg num 129

 

#

[ 26

01

05

-- ] DTLPWRSOMC Parameter

not supported -- chk fld

ptr.

DEFINE_EVENT

101176

CRITICAL

DEFAULT

# msg num 130

 

#

[ 26

02

05

-- ] DTLPWRSOMC Parameter

value invalid -- chk fld

ptr.

DEFINE_EVENT

101276

CRITICAL

DEFAULT

# msg num 130

 

#[ 26 03 05 -- ] DTLPWRSOMC Threshold parameters not supported.

DEFINE_EVENT

101376

CRITICAL

DEFAULT # msg num 184

#

[ 27

00

05

-- ]

 

 

DEFINE_EVENT

101476

CRITICAL

DEFAULT # msg num 188

#

[ 2c

00

0b

-- ]

 

 

DEFINE_EVENT

101576

CRITICAL

DEFAULT # msg num 185

#

[ 3a

00

05

-- ]

 

 

DEFINE_EVENT

101676

CRITICAL

DEFAULT # msg num 132

#[ 3d 00 05 -- ] DTLPWRSOMC Invalid bits in identify message.

DEFINE_EVENT 101776 CRITICAL

DEFAULT # msg num 133

#[ 43 00 05 -- ] DTLPWRSOMC Message error.

DEFINE_EVENT

101876

CRITICAL

DEFAULT

#

msg num

189

#

[ 43 00

0b -- ]

 

 

 

 

 

DEFINE_EVENT

101976

CRITICAL

DEFAULT

#

msg num

134

#[ 49 00 05 -- ] DTLPWRSOMC Invalid message error.

DEFINE_EVENT

102076

 

CRITICAL

DEFAULT # msg num

190

#

[ 4e

00

0b --

]

 

 

 

DEFINE_EVENT

102176

 

CRITICAL

DEFAULT # msg num

135

#

[ 58

00

05 --

]

-------O--

Generation does not

exist.

DEFINE_EVENT

102276

 

CRITICAL

DEFAULT # msg num

136

#

[ 64

00

05 --

]

-----R----

Illegal mode for this track.

DEFINE_EVENT

102376

 

CRITICAL

DEFAULT # msg num

186

#

[ 80

01

06 --

]

 

 

 

112

Chapter 5

Page 112
Image 112
HP B6191-90029 manual Defineevent 100075 Critical, Defineevent 100376 Critical, Defineevent 100476 Critical