Hardware Monitor Configuration Files
SEVERITY_ACTION | INFORMATION | NOTIFY |
SEVERITY_ACTION MINOR_WARNING | NOTIFY | |
SEVERITY_ACTION MAJOR_WARNING | NOTIFY | |
SEVERITY_ACTION | SERIOUS | NOTIFY |
SEVERITY_ACTION | CRITICAL | NOTIFY |
#****************************************************************************#
#* | *# |
#* | event# |
#* | *# |
#****************************************************************************#
DEFINE_EVENT | 3 | INFORMATION | DEFAULT # Target Operating conditions changed |
DEFINE_EVENT | 4 | INFORMATION | DEFAULT # Microcode has been changed |
DEFINE_EVENT | 6 | INFORMATION | DEFAULT # Inquiry data has changed |
DEFINE_EVENT | 7 | CRITICAL | DEFAULT # Failed write operation |
DEFINE_EVENT | 8 | CRITICAL | DEFAULT # Auto reallocation failed |
DEFINE_EVENT | 9 | CRITICAL | DEFAULT # Reconstruction Failed (write) |
DEFINE_EVENT | 10 | SERIOUS | DEFAULT # Reconstruction failed (read) |
DEFINE_EVENT | 11 | CRITICAL | DEFAULT # Unrecovered Read/write error |
DEFINE_EVENT | 12 | CRITICAL | DEFAULT # Deferred error caused drive warning |
DEFINE_EVENT | 13 | CRITICAL | DEFAULT # Hardware component diag failure |
DEFINE_EVENT | 14 | CRITICAL | DEFAULT # Failed testUnit ready command |
DEFINE_EVENT | 15 | CRITICAL | DEFAULT # Format unit command failed |
DEFINE_EVENT | 16 | SERIOUS | DEFAULT # Mode select command failed |
DEFINE_EVENT | 17 | SERIOUS | DEFAULT # Drive failed because deferred error |
DEFINE_EVENT | 18 | CRITICAL | DEFAULT # Drive replacement error |
DEFINE_EVENT | 19 | MAJOR_WARNING DEFAULT # Excessive Media error rate | |
DEFINE_EVENT | 20 | MAJOR_WARNING DEFAULT # Excessive Seek Error rate | |
DEFINE_EVENT | 21 | MAJOR_WARNING | DEFAULT # Excessive grown defects |
DEFINE_EVENT | 22 | SERIOUS | DEFAULT # No response from a drive |
DEFINE_EVENT | 23 | SERIOUS | DEFAULT # Communication errors |
DEFINE_EVENT | 24 | SERIOUS | DEFAULT # No drive present when it should be |
DEFINE_EVENT | 25 | CRITICAL | DEFAULT # Subsystem component failure |
DEFINE_EVENT | 26 | MINOR_WARNING | DEFAULT # AC power fail. On battery. |
DEFINE_EVENT | 27 | CRITICAL | DEFAULT # AC power fail. 2 minutes to shutdown |
DEFINE_EVENT | 28 | CRITICAL | DEFAULT # AC power fail, DC power gone. |
DEFINE_EVENT | 29 | INFORMATION | DEFAULT # AC power was lost, now back |
116 | Chapter 5 |