Hardware Monitor Configuration Files

Monitor-Specific and Global Configuration Files

#

[ 4b 00

06 --

] DTLPWRSOMC Data phase error.

#

---------------------------------------------------------

 

 

 

DEFINE_EVENT

100053

CRITICAL

DEFAULT

# msg num 92

#

[ 10 00

04 --

] D---W--O--

Id crc or

ecc error.

#

---------------------------------------------------------

 

 

 

DEFINE_EVENT

100054

CRITICAL

DEFAULT

# msg num 93

#[ 2b 00 06 -- ] DTLPWRSO-C Copy cannot execute; host cannot disconnect.

#---------------------------------------------------------

DEFINE_EVENT

100055

CRITICAL

DEFAULT # msg num 94

#

[ 11 0a

04 --

] DT

-----O--

Miscorrected error.

#

---------------------------------------------------------

 

 

 

DEFINE_EVENT

100056

CRITICAL

DEFAULT # msg num 95

#

[ 11 03

04 --

] DT

--W-SO--

Multiple read errors.

#

---------------------------------------------------------

 

 

 

DEFINE_EVENT

100057

CRITICAL

DEFAULT # msg num 96

#[ 44 00 04 -- ] DTLPWRSOMC Internal target failure.

#---------------------------------------------------------

DEFINE_EVENT 100158 CRITICAL

DEFAULT # msg num 97

#[ 15 01 04 -- ] DTL-WRSOM- Mechanical positioning error.

DEFINE_EVENT

100258

CRITICAL

DEFAULT #

msg num 97

#

[ 3b 00

-- --

]

 

 

#

---------------------------------------------------------

 

 

 

DEFINE_EVENT

100059

CRITICAL

DEFAULT #

msg num 98

#

[ 15 02

04 --

] DT--WR-O--

Positioning

error detected by read of medium.

#

---------------------------------------------------------

 

 

 

DEFINE_EVENT

100060

CRITICAL

DEFAULT #

msg num 99

#[ 15 00 04 -- ] DTL-WRSOM- Random positioning error.

#---------------------------------------------------------

DEFINE_EVENT

100061

CRITICAL

DEFAULT # msg

num 100

#

[ 01

00

04 --

] D---

W--O--

No index/sector signal.

#

---------------------------------------------------------

 

 

 

 

 

DEFINE_EVENT

100062

CRITICAL

DEFAULT # msg num 101

#

[ 02

00

04 --

] D---

WR-OM- No seek complete.

#

---------------------------------------------------------

 

 

 

 

 

DEFINE_EVENT

100063

CRITICAL

DEFAULT # msg num 102

#

[ 03

00

04 --

] DTL-W-SO--

Peripheral device write fault.

#

---------------------------------------------------------

 

 

 

 

 

DEFINE_EVENT

100064

CRITICAL

DEFAULT # msg num 103

#

[ 09

00

06 --

] DT--

WR-O--

Track following error.

#

---------------------------------------------------------

 

 

 

 

 

110

Chapter 5