Troubleshooting and Removal/Replacement Procedures

H/W Path

Class

Description

============================================

 

bc

 

 

8

bc

I/O Adapter

8/0

ext_bus

GSC built-in Fast/Wide SCSI Interface

8/0.0

target

 

 

8/0.0.0

disk

QUANTUM LPS1080WD

8/0.5

target

 

 

8/0.5.0

disk

DEC

DSP3210SW

8/0.6

target

 

 

8/0.6.0

disk

DEC

DSP3210SW

8/12

ba

Core I/O Adapter

8/12/5

ext_bus

Built-in SCSI

8/12/5.3

target

 

 

8/12/5.3.0

tape

HP C1537A

8/12/5.4

target

 

 

8/12/5.4.0

disk

SEAGATE ST3600N

8/12/5.6

target

 

 

8/12/5.6.0

disk

MICROP

2112

10

bc

I/O Adapter

10/12

ext_bus

GSC add-on Fast/Wide SCSI Interface

10/12.4

target

 

 

10/12.4.0

disk

SEAGATE ST31200W

Checking the Hardware Installation

Perform the following steps to check the hardware installation:

CAUTION: The DDS-3 drive is susceptible to mechanical and electrostatic shock. When handling the drive, always wear the static strap that came in the DDS-3 drive kit. Always handle the drive carefully.

1.Check that the SCSI-2 terminator is connected to the single-ended SCSI-2 port on the rear I/O panel of the system unit (if there are no external SCSI-2 devices), or that the last external single-ended SCSI-2 device is terminated.

3±3