Using Your DDS Drive

LEDs

The front panel has two colored LEDs: the Tape Light and the Clean/Attention Light. The Tape Light flashes green to show activity (loading, unloading, reading, and writing). Steady green means a cartridge is loaded.

The Clean/Attention Light flashes amber to indicate head cleaning is needed or a cartridge is near the end of its life. Steady amber means a hard fault.

Table 2±1. LED Display Codes

 

Tape

Clean/

Meaning

 

 

 

 

 

Key

 

Light

Attention

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activity ± load or unload

 

 

 

 

 

Steady Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activity ± read or write

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady Amber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cartridge loaded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Any

 

 

 

Cleaning needed

 

 

 

 

 

1/2 sec on, 1/2 sec off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing Amber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Any

 

 

 

Fault

 

 

 

 

 

1/2 sec on, 1/2 sec off

 

 

 

 

 

 

 

 

 

Fast Flash Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4 sec on, 1/4 sec off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Cassettes

Media Life

HP DDS data cassettes are currently specified to 2000 passes over any part of the tape under optimal environmental conditions (50% relative humidity, 22 degrees C). During a tape operation, any one area of the tape may have multiple passes over the heads. This translates into approximately 200 to 300 backups or restores.

Under certain conditions, the life of your data cassette is less than 200 to 300 backups or restores. Replace your data cassettes after 100 backups or restores if your operating conditions meet any of the following criteria:

2±3