POST Error Messages
POST Error Messages (Continued)
Screen Message | Probable Cause | Recommended Action |
One or more SATA | |
Error | devices are improperly |
| attached. For optimal |
| performance, the SATA 0 |
| and SATA 1 connectors |
| must be used before |
| SATA 2 and SATA 3. |
Ensure SATA connectors are used in ascending order. For one device, use SATA 0. For two devices, use SATA 0 and SATA 1. For three devices, use SATA 0, SATA1, and SATA 2.
Internal temperature | Check that computer air vents are not | |
| exceeds specification. | blocked and the processor cooling fan is |
|
| running. |
|
| Verify processor speed selection. |
|
| Replace the processor. |
|
| Replace the system board. |
|
|
|
Processor not supported | Upgrade BIOS to proper version. | |
Error | by ROM BIOS. | Change the processor. |
|
|
|
Recently installed | If processor was recently replaced, | |
Supported | processor may not be | restore the original processor to see if the |
| supported by the system | problem remains. |
| board. | Check product documentation for |
|
| processor support information. |
|
|
|
Invalid Electronic Serial | Electronic serial number | Run Computer Setup. If Setup already |
Number. | has become corrupted. | has data in the field or will not allow the |
|
| serial number to be entered, download |
|
| from http://www.hp.com and run |
|
| SP5572.EXE (SNZERO.EXE). |
|
| Run Computer Setup and try to enter |
|
| serial number under Security, System ID, |
|
| then save changes. |
|
|
|
Service Reference Guide, dc7600 |