Use the HP sp400 Series Configuration Software

Imager tab

The Imager tab allows you to configure factors that affect the operation of the All-in-One imager module. The All-in-One uses the Hand Held Products 5X80 imager module.

For additional information about configuring the imager, see the HandHeld Products 5X80 User’s Guide available for download at www.handheld.com.

Initialization String: A string of commands that are sent to the imager when the All-in-One is turned on.

Termination String: A string of characters that are added to the end of the scanned string. To enter non-ASCII characters, use a forward slash followed by two hex digits. A single forward slash may be entered as //.

Imager Pre-Trigger: Selecting the Pre-Trigger check box causes the imager to enter the triggered state immediately after a scan is complete.

Barcode Read Pre-presentation Timeout (ms): The number of milliseconds the imager waits to scan a bar code before it exits the triggered state.

NOTE: The Barcode Read Pre-presentation Timeout (ms) box is only activated when the Pre- Trigger check box is selected.