2.4 End-Bus RAID Cluster Layout - (SCSI Bus Interconnect)

To connect two HP host servers to a RAID subsystem located on the end of the SCSI bus (e.g., an End-Bus RAID cluster layout), reference Figure 2-3 and follow these steps:

1.Attach a Y-cable (BN21W-0B) to the HD68-pin host adapter on Host A.

2.Attach a Y-cable (BN21W-0B) to the HD68-pin host adapter on Host B.

3.Attach one end of the HD68-pin straight-thru cable (BN21K-05) to a convenient end of the Y-cable attached to Host A.

4.Connect the other end of the cable to a convenient end of the Y-cable attached to Host B.

5.Attach the compatible end of the 5M adapter cable (BN38C-05) to the available end of the HD68-pin Y-cable attached to Host B.

6.Connect the other (VHDCI-compatible) end of the adapter cable to the available end of a tri-link connector on a subsystem controller.

7.Connect terminator H8863-AA to the available end of a tri-link connector on a subsystem controller.

8.Connect terminator H879-AA to the available end of the Y-cable attached to Host A.

Figure 2–3 End-Bus RAID Cluster Layout - (SCSI Bus Interconnect)

H OST A

HO ST B

RA7000 or ESA10000

 

Subsystem

 

 

 

 

H D 68 H ost

HD 68 Ho st

 

 

A dapte r

Ad ap te r

 

Term inator

 

 

 

BN 21W -0B

BN 21W -0B

BN 37 A -0E

H8863-AA

Tri-Link

 

Y -C ab le

Y -C ab le

 

 

 

Term ina tor

BN2 1K -05

B N38C -0 5

H 8 79-AA

H D68 Straight-Thru

VHD C I-to-H D 68

 

 

Adapter C able